TecnoVideo WP10EX Series Installation Manual Download Page 6

 

USAGE 
 

Filling the tank 

Pull  the  red  safety  valve  to  assure  that  the  pump  is  not  under 
pressure.  
Rotate  counterclockwise  the  pumping  element  to  unscrew  it  and 
remove it. Fill the tank with maximum 10 litres of liquid.  
The quantity of washing cycles with a single refill is about 200-500 
(results  may  vary  depending  on  camera  height,  pressure,  water 
level). 
Fix the pumping element, checking that the O-ring and its seating 
are clean. Pressurize only using the pumping element. 

Do  not  force  the  safety  valve.  Do  not  unscrew  the  hand  pump  if  the 
tank  is  under  pressure.  The  unit  is  intended  to  be  used  with  water  or 
with water solutions: denser mixtures could obstruct the nozzle. If the 
solution  used  has  residual,  it  must  be  filtered  before  use.  Do  not  use 
inflammable  liquids,  hydrogen  peroxide  (nor  similar  substances  that 
give  off  oxygen),  corrosive  substances,  liquids  containing  ammonia, 
solvents  and  liquids  containing  solvents,  viscous  or  greasy  liquids, 
liquids that form residues (dyes and greases). 

 
 
 
 
 

Pumping element 

 
 
Safety valve 
 
 
 
 
 
 
 
 
 
 
 

Usage 

Unlock the pump handle by pushing it down and rotating it. After 
a few moments pull the safety valve to check that it's not blocked 
and that air goes out. Pump until the desired pressure is reached.  

Maximum pressure is 4 bar.

  

Lock the handle. When the camera water jet weakens, it is needed 
to restore the internal pressure. Eventually close the cabinet. 

 

Maintenance and filter replacement 

This  equipment  has  been  designed  to  fit  in  harsh  environments  requiring  little  or  no  maintenance.  Suggested 
inspection  interval  is  6  months,  but  extremely  harsh  environments  may  require  more  frequent  inspection  and 
maintenance checks. On each inspection check the proper working of the red safety valve. Also, on each inspection 
check O-ring seals. Replace them if necessary. Check tank, hand pump and pressure gauge integrity. If any damage is 
noticed, please contact Tecnovideo for spare parts. 
Check  cables,  electrical  connections  and  mounting  hardware  for  integrity  and  tightness.  Replace  or  tighten  any 
damaged/loose part. 

Check the filter between the tank and the solenoid valve. 
It is suggested to replace the filter on a yearly basis (one spare filter 
is  provided  with  MKWP10EX  maintenance  kit).  Replacement 
interval  may  be  shorter,  depending  on  the  impurities  level  in  the 
water. 
To replace the filter, pull red safety valve on the top of the tank to 
assure  that  the  pump  is  not  under  pressure.  Disconnect  the  filter 
from  the  hoses  through  the  quick  connect  fittings.  Connect  the 
new clean filter. 

Do not disconnect the filter if the tank is under pressure. 
When  connecting  the  new  filter,  pay  attention  to  the  arrows  marked 
on  the  filter  body,  these  indicates  the  water  flow.  Connect  the  two 
hoses to the filter according to the arrows/water flow direction. 

 
 

        Flow direction 
 
 
Filter 
 
 
 
Solenoid 
valve 

 

 

               

 

 
 
 
 

 

 

 
 

6

 

 

Summary of Contents for WP10EX Series

Page 1: ...WP10EX Pressurized Washer System with integral solenoid valve Installation manual Issue 20200115...

Page 2: ...IMINARY REMARKS 03 INSTALLING THE UNIT 05 Opening the washer system 05 Electrical connections 05 WP10EXe connection diagram 05 WP10EXd connection diagram 05 Passing the cables 05 USAGE 06 Filling the...

Page 3: ...his manual and in the solenoid valve installation manual Heed all warnings Unpack this equipment and handle it carefully If the package appears to be damaged notify the shipper immediately Use the ori...

Page 4: ...n all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding parts in case that terminal blocks screw off Electrical connections such as...

Page 5: ...nnection must be performed via the solenoid valve cable gland included Check the valve label for the correct supply voltage When supply voltage is provided the solenoid valve will open letting the wat...

Page 6: ...it is needed to restore the internal pressure Eventually close the cabinet Maintenance and filter replacement This equipment has been designed to fit in harsh environments requiring little or no maint...

Page 7: ...ELECTRICAL DIAGRAM In the diagram below it is shown how to control WP10EX Series washer systems via a Dry Contact Relay input To do so it is needed the DCI EXWP interface sold separately 7...

Page 8: ...For more information about collection and recycling of old products please contact your local municipality or your waste disposal service Penalties may be applicable for incorrect disposal of this wa...