INSTALLING THE UNIT 

 

Opening the washer system 

Loosen the two M6 screws to remove the cover and to access the 
internal parts. 
Do not remove the screws. 

 
 
 
 
 
 
 
 
 
 
 

Screws 

Passing the cables 

There  are  5  fairleads  placed  2  at  the  bottom  and  3  on  the  side  of 
the frame. Push the cable and the water hose to enter the cabinet. 

No cable gland is required for cable entry into the cabinet. 

 
 
 
 
 
 
 
 
Fairlead 
 

Electrical connections 

Perform the electrical connections either from a telemetry or from 
a proper switching system to the solenoid valve. 
The  connection  must  be  performed  via  the  solenoid  valve  cable 
gland (included).  
Check the valve label for the correct supply voltage. 
When  supply  voltage  is  provided,  the  solenoid  valve  will  open 
letting the water output. 

Be sure to properly connect the ground to every marked point. 

 
 
 

 
Water from 
tank 
 
 
 
Solenoid 
valve 

 

 

               

 

 
 
 
 

WP10EXe connection diagram 

The  connection  diagram  of  the  valve  (WP10EXe  versions)  is  as  it 
follows: 
- Neutral on Pin 1; 
- Line on Pin 2 (a fuse between Line and Pin 2 is needed); 
- GND on Pin 3. 

 

WP10EXd connection diagram 

The  connection  diagram  of  the  valve  (WP10EXd  versions)  is  as  it 
follows: 
- Supply voltage between Pin 1 and Pin 2 (a fuse between Line and 
the pin is needed); 
- GND on Pin 3. 

 

 
 
 
 

 

Magnet 

 

 

5

 

 

Magnet

 

1~

 

2

 

3

 

brown

 

blue

 

green/yellow

 

Summary of Contents for WP10EX Series

Page 1: ...WP10EX Pressurized Washer System with integral solenoid valve Installation manual Issue 20200115...

Page 2: ...IMINARY REMARKS 03 INSTALLING THE UNIT 05 Opening the washer system 05 Electrical connections 05 WP10EXe connection diagram 05 WP10EXd connection diagram 05 Passing the cables 05 USAGE 06 Filling the...

Page 3: ...his manual and in the solenoid valve installation manual Heed all warnings Unpack this equipment and handle it carefully If the package appears to be damaged notify the shipper immediately Use the ori...

Page 4: ...n all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding parts in case that terminal blocks screw off Electrical connections such as...

Page 5: ...nnection must be performed via the solenoid valve cable gland included Check the valve label for the correct supply voltage When supply voltage is provided the solenoid valve will open letting the wat...

Page 6: ...it is needed to restore the internal pressure Eventually close the cabinet Maintenance and filter replacement This equipment has been designed to fit in harsh environments requiring little or no maint...

Page 7: ...ELECTRICAL DIAGRAM In the diagram below it is shown how to control WP10EX Series washer systems via a Dry Contact Relay input To do so it is needed the DCI EXWP interface sold separately 7...

Page 8: ...For more information about collection and recycling of old products please contact your local municipality or your waste disposal service Penalties may be applicable for incorrect disposal of this wa...

Reviews: