![TecnoVideo WP10EX Series Installation Manual Download Page 5](http://html1.mh-extra.com/html/tecnovideo/wp10ex-series/wp10ex-series_installation-manual_1072286005.webp)
INSTALLING THE UNIT
Opening the washer system
Loosen the two M6 screws to remove the cover and to access the
internal parts.
Do not remove the screws.
Screws
Passing the cables
There are 5 fairleads placed 2 at the bottom and 3 on the side of
the frame. Push the cable and the water hose to enter the cabinet.
No cable gland is required for cable entry into the cabinet.
Fairlead
Electrical connections
Perform the electrical connections either from a telemetry or from
a proper switching system to the solenoid valve.
The connection must be performed via the solenoid valve cable
gland (included).
Check the valve label for the correct supply voltage.
When supply voltage is provided, the solenoid valve will open
letting the water output.
Be sure to properly connect the ground to every marked point.
Water from
tank
Solenoid
valve
WP10EXe connection diagram
The connection diagram of the valve (WP10EXe versions) is as it
follows:
- Neutral on Pin 1;
- Line on Pin 2 (a fuse between Line and Pin 2 is needed);
- GND on Pin 3.
WP10EXd connection diagram
The connection diagram of the valve (WP10EXd versions) is as it
follows:
- Supply voltage between Pin 1 and Pin 2 (a fuse between Line and
the pin is needed);
- GND on Pin 3.
Magnet
5
Magnet
1~
2
3
brown
blue
green/yellow