Electronic set-up
Using the ET interface, set up the Auxiliary system – One way, one pump, mechanical relief, basic version.
Pressure functionality according to the SIS indication and machine configuration.
WARNING:
as this is a Prime version (basic) kit, some option features as speed reductions, pressure sensors, etc. are not
implemented, even in case of pressure sensor has been included in the kit.
Please double check the set up configuration before operate the machine and verify that all options are
indicated as “Not installed”.
Please set up the ECM as follow
Machine appl.: Multiproc
Total load pressure sensors: 2
Attachment valve #1 and #2 configuration: one or two ways
ATT Valve #3, #4: not installed
Variable relief #1 and #2: not installed
Multi function with combined attachments: not installed
Return filter: not installed
Solenoid variable relief (E-RV1, E-RV2): not installed
Activation: Rh modulation handle (or switch if available and preferred)