DIMENSIONS
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTION
Only use TECNOSICUREZZA supplied screws (M6) to mount the lock. Tighten the
screws securely so the lock body is attached firmly to the mounting surface
(Torque approximately 3,5 Nm).
In the LOCKED position, there should be approximately 1 mm
clearance between the lock bolt and the cavity in the blocking bar
of the boltwork. The lock bolt must move freely into the cavity.
In OPEN position, there should be
minimum 3mm and maximum 5 mm
clearance between the lock bolt and
the bloching bar of the boltwork.
Important:
•
Max load on the bolt should not exceed 1KN.
•
Modifications to the lock (including lock bolt attachments) are not allowed,