Instruction manual hose reel
14
30/07/15 Rev:1.0.0
CENTRAL VACUUM SYSTEMS
ByTecnoplus
s.r.l.
12 - TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
The air suction is weak
More than one suction socket
is being used at the same
time and/or the service
suction socket is working
Chiudere le altre prese
di aspirazione sino a
raggiungere la potenza
aspirante richiesta
The fl exible hose or the
cleaning accessories are
broken
Verifi care l’integrità del tubo
fl essibile e degli accessori (e
nel caso sostituirli)
There is a clogging in the
suction pipes of the pipe
network
Chiamare il Servizio
Assistenza
The fl exible hose is obstructed
Check and clean, if
necessary
Vacuum cleaner unit
Read the instruction manual
of the vacuum cleaner unit
The hose reel does not turn
Hose reel wheel blocked
Call the Technical Service
Spiral spring broken
Call the Technical Service
Hose reel doesn’t get lock
Moving system broke
Call the Technical Service