When installing the unit the following prescriptions
must be complied with:
• The gas safety (installation & use) regulations of
1984
• The gas safety (installation & use) regulation
(Amendment 1990)
• Local prescriptions, such as building standards and
prescriptions concerning combustion
• Directives and regulations of the gas supply
company and of the power supply company
• Health and safety at work etc. Act 1974
• The unit must only be installed in rooms where there
is sufficient ventilation.
Law provisions, technical regulations and norms
Technical data
Gas connection
Prior to connecting the unit to the gas mains, check
the data plate to see if the unit has been set and tested
for the type of gas available.
If the gas type given on the data plate is not the
same as that available, please refer to the paragraph
“Conversion or Adaptation”.
Connect up to the gas mains using metal pipes
with a suitable diameter; install an approved cutoff
cock between them.
If flexible pipes are used they must be in stainless
steel according to the standard in force.
The connection ramp on the unit complies with the
ISO 7-1 standard, and the thread is external. TThe
connection is located at the rear or at the bottom
depending on the model.
Only an authorized firm may connect the unit.
Once the unit has been installed, use operating
pressure to check for leaks on the fittings; foamy sub-
stances would be ideal for this purpose as they do not
cause corrosion, e.g. a leak finder spray.
Note:
When checking for leaks do not use bare
flames!
Nozzle table
FT...35G/0
FT...70G/0
FT...35G/G6
FT...70G/G6
Thermal nominal power (kW)
4
8
Minimum thermal power (kW)
1,8
3,6
Consumption
nom.
min.
nom.
min.
Natural gas H (Hi = 9,45kWh/m3) m3/h
0,42
0,19
0,84
0,38
LPG
(Hi = 12,68 kWh/kg) kg/h
0,31
0,14
0,62
0,28
Natural gas H 20mbar
LPG 28-30/37mbar
Primary air
Natural gas H
3 mm
3 mm
Distance H
LPG
15 mm
15 mm
Nominal power
160
2 x 160
Minimum
Adjustable
Adjustable
Nominal power
100
2 x 100
Minimum
80
2 x 80
nozzle ø in
1/100 mm
Evacuating burnt products
This unit belongs to construction type A therefore it
does not have to be connected to a flue.