background image

GECA

 Srl   

Via E. Fermi, n°98  25064 Gussago (BS) 

Italy Tel. +39 030 3730218  

www.gecasrl.it

Tecnocontrol 

Srl   

Via Miglioli, n°47  20090 Segrate (MI) 

Italy  Tel. +39 02 26922890 

www.tecnocontrol.it

TECHNICAL CHARACTERISTICS

- Power:   

Lithium battery 3V - 1400 mAh (NOT replaceable)

- Battery life:  

more than 6 years (in normal operation)

- Sensor life:  

more than 6 years in a domestic environment according  

 

 

to specifications.

- Working temperature:  

-10 ° C ... + 45 ° C.

- Relative humidity:   

30% ... 90% UR.

- Sensor operation limit:  

5000 ppm max 15 minutes

- Maximum storage time:  

6 months

- Intervention thresholds:

 

 

 

l

50 ppm for 70 minutes.

 

 

 

l

100 ppm for 20 minutes.

 

 

 

l

300 ppm for 1 minute.

- Acoustic signal:    

80 dB (A) to 1 meter.

- Protection degree:  

IP42.

- Electronic self-diagnosis with anomaly signal.

- The CO alarm device conforms to the European standard EN 50291-1: 2010 

“Electrical devices for the detection of carbon monoxide in domestic environ-

ments”.

SALES CONDITION

THE PRESENT CERTIFICATE IS THE ONLY DOCUMENT TO HAVE THE RIGHT OF 

REPARATION OF DEVICE IN WARRANTY

• The product is warranted for 24 month from purchase date. 

• Any damages caused by tampering and incorrect use or installation will be 

not covered by warranty. 

• The warranty is valid only if is full compiled. 

• In case of defects covered by warranty, the producer will repair or replace 

the free product.

PERFORMANCES OUT OF WARRANTY:

When warranty’s terms are spent, the eventual reparations will debited in ac-

cording to the replaced parts and to the hand costs.

WARRANTY CERTIFICATE

COMPILE AND SEND IN CASE OF DAMAGE.

DEVICE:

           

  serie 

Beta

 mod. 762/CO                      serie 

Beta

 mod. SE325EC

 

Serial number (s.n.)___________________________________________

DEALER

Stamp:

 

 

 

 

 

  Date of purchase:

 

 

 

                       ________/________/________

USER

Surname and name____________________________________________
Address______________________________________N°_____________
City_________________________________________________________
Telephone____________________________________________________

TO COMPILE BY THE INSTALLER:

Installation date ______________________________________________ 
Substitution date _____________________________________________ 
Installation local ______________________________________________ 
Instruments’ serial number ______________________________________

                                  (to read on the frontal plastic involucres)

 

 

 

 

 

Stamp

Sign

 ______________________________________________________

The manufacturer firm reserves the right to make any aesthetic or functional  modification to the without prior 

notice at any time.

1) Open doors and windows to increase the ventilation of the environ-

ment.

2) Close the gas counter tap and stop using any combustion device.

3) If the alarm continues and the cause of gas leak is not detectable 

or  negligible,  abandon  the  property  and,  from  the  outside,  alert  the 

emergency service.

4) If there were people with nausea or headache symptoms, immedi-

ately call the health emergency number.

If the alarm stops, it is necessary to identify the cause that has caused 

it and to act accordingly.

ATTENTION!

In the event of an alarm:

We warmly suggest doing a check-test of the detector working, car-

ried-out from your installer - at least once a year.

PERIODICAL VERIFICATIONS

WARNING

To clean the appliance, use a cloth to remove the dust on the case. 

Keep in mind that the sensor has good resistance to commonly used 

products  such  as  sprays,  detergents,  alcohol,  glues  or  paints,  but 

these products can contain substances that, in large quantities, inter-

fere with the sensor causing false alarms. 

It is advisable to ventilate the room when using these products.

Solvent or silicone vapors can deteriorate the gas sensor even during 

storage in the warehouse.

The use of the gas detector outside the temperature range and hu-

midity indicated may damage the sensor and reduce its life duration.

It is reminded that the detector is unable to detect leaks that occur 

outside the room where it is installed either inside the walls or under 

the floor.

Dis. 0134183    Cod. 2.710.2991

l

 silence  the BUZZER sound (

Beep

) when the detector is in ALARM 

status with a concentration below 300 ppm.

The gas detector will stop “

Beep

” for 15 minutes while the RED LED 

will continue to flash.

After 15 minutes if there is still a concentration of harmful carbon mo-

noxide (CO), BUZZER will be automatically switched on.

5

6

Summary of Contents for Beta Series

Page 1: ...bile alla concen FUNZIONAMENTO GENERALITA L installazione di questo apparecchio non deve essere considerata come sostituto dell installazione dell uso e della manutenzione corretti di apparecchi a combustione compresi sistemi di ventilazione e scarico idonei Il presente apparecchio è stato progettato per proteggere le persone dagli effetti acuti dell esposizione al monossido di carbonio Esso non p...

Page 2: ...eep e fa lampeggiare il LED ROSSO Se il rivelatore gas Beta è in stato di ALARM per più di 15 minuti per risparmiare la carica della batteria riduce la frequenza dei Beep e dei lampeggi del LED ROSSO Solo se la quantità di gas misurata nell aria è inferiore a 300 ppm è possibile far tacere il buzzer per un periodo di tempo di 15 minuti premendo il tasto TEST HUSH paragrafo TEST HUSH Trascorso tale...

Page 3: ...zione acustica 80 dB A a 1 metro Grado di protezione IP42 Autodiagnosi elettronica con segnalatore eventuali anomalie Il dispositivo di allarme per CO è conforme alla norma europea EN 50291 1 2010 Apparecchi elettrici per la rilevazione di monossido di carbonio in am bienti domestici CONDIZIONI GENERALI DI GARANZIA IL PRESENTE CERTIFICATO È L UNICO DOCUMENTO CHE DÀ DIRITTO ALLA RIPARAZIONE DEL RIV...

Page 4: ...es The Beta gas detector has a sensitive element to the concentration of carbon monoxide in the air GENERAL OPERATIONS Installation of this appliance should not be considered as a substitute for proper installa tion operation and maintenance of combustion appliances including suitable ventilation and drainage systems This unit is designed to protect people from the acute effects of exposure to car...

Page 5: ...ctor is in ALARM status for more than 15 minutes to save battery charge it reduces the Beep frequency and red LED flashes Only if the amount of gas measured in air is less than 300 ppm it is possible to silence the buzzer for a period of 15 minutes by pressing the TEST HUSH button see TEST HUSH paragraph After that period if the gas concentration exceeds the alarm thresh olds the BUZZER will be au...

Page 6: ...____ Substitution date _____________________________________________ Installation local ______________________________________________ Instruments serial number ______________________________________ to read on the frontal plastic involucres Stamp Sign ______________________________________________________ The manufacturer firm reserves the right to make any aesthetic or functional modification to...

Reviews: