ALARM LIST
Testo
display
utente
Alarm description
Alarm log
(CAT)
FULL
LOSS
Load interruption for burner too full. The FULL signal occurs when the
tank is completely filled. The stove will emit a sound signal along with
the word FULL, obviously this only happens if the stove is powered. If the
user fills the bioethanol full with a disconnected plug, the unit will emit
a sound when it is switched on because it is full and the word FULL will
appear.
This signal warns that there is a bioethanol spill that can be caused by
the user’s tapping, but also in the unlikely event of a tank or pump leak.
Since alcohol evaporates in a short time, the content in the collecting
pan with its display status disappears after a period of time, whereas if
there is a leak, tank, pump, or tube Of the connection, the user is then
notified of the anomaly. If the problem persists, contact your authorized
service center.
TILT
Operation block for anti-fallen stove sensor operation. Check the correct
positioning of the stove. If the problem persists, contact your qualified
service center.
SF
Flame Stop (if the thermocouple detects a temperature lower than a
set value, interpreting this as a flame-out). Repeat the ignition. If the
problem persists, contact your authorized service center.
H3
AF
Ignition failure (if a flame does not appear in a 15 minute time or the
start temperature is not reached). Repeat the ignition, if an error occurs,
contact your authorized service center.
H4
H5
Black out: power off for power failure. Reset the power supply, restart
the ignition, if the problem persists, contact your authorized service
center
H5
H6
Thermocouple faulty or disconnected.
Contact your authorized service center.
H6
H7
Temperature abnormality
(Switch off at excessive temperature)
Fully cool the stove, restart the ignition, if the problem persists contact
the authorized service center
H7
Bat1
Battery clock finished (type CR2032)
Contact the service center
-