www.tecnikchargers.com
www.tecnikchargers.com
6
6
CHARGER DESCRIPTION
TRONIK
chargers have been designed to charge lead-acid batteries. These units convert the A.C. input to a D.C. output at
the correct voltage with a Wa type charge curve.
TRONIK
charger operation is managed by the
MTL
digital charge controller, which is a microprocessor based electronic
board of the last generation. Important features of the controller are:
Gassing point (80%) programming by DIP switches
Proportional Algorithm for charge time calculation
Programmable Equalize System (Automatic Pulsed & Manual)
Automatic voltage-controlled maintenance
Wrong battery detection
Battery desulphation cycle
Independent safety timer
Automatic data-saving in case of A.C. input black out
Cyclical indication of V/cell, AMPS, Ah returned, time
Cool down time counter
Scrolling messages in plain text
The
MTL
charge controller monitors the entire charging curve, and it incorporates several safety features.
The front panel contains the digital display (4-Digits), the STOP button and the MANUAL-EQUALIZE button.
Charge cycle
Equalizing
Time
Voltage (V)
Current (A)