TECNARE V 10 User Manual Download Page 5

V series User’s Manual 

5/28 

bookcase or rack unless proper ventilation 

is 

provided 

or 

the 

manufacture's 

instructions have been adhered to. 

8.  DO  NOT  INSTALL  NEAR  ANY  HEAT 

SOURCES 

This Product should be situated away from 

heat  sources  such  as  radiators,  stoves,  or 

other  products  (including  amplifiers)  that 

produces heat. 

9.  DO  NOT  DEFEAT  THE  SAFETY 

PURPOSE  OF  THE  POLARIZED  OR 

GROUNDING-TYPE PLUG 

A  Polarized  plug  has  two  blades  with  one 

wider  than  the  other.  A  grounding-type 

plug has two blades and a third grounding 

prong. The wide blade or the third prongs 

are  provided  for  your  safety.  If  the 

provided plug does not fit into your outlet, 

consult  an  electrician  for  replacement  of 

the obsolete outlet. 

10. PROTECT THE POWER CORD FROM 

BEING  WALKED  ON  OR  PINCHED 

PARTICULARLY 

AT 

PLUGS, 

CONVENIENCE 

RECEPTACLES, 

AND 

THE  POINT  WHERE  THEY  EXIT  FROM 

THE APPARATUS. 

11. 

ONLY 

USE 

ATTACHMENTS 

ACCESSORIES 

SPECIFIED 

BY 

THE 

MANUFACTURER. 

12.  USE  ONLY  WITH  CART,  STAND, 

TRIPOD, 

BRACKET, 

OR 

TABLE 

SPECIFIED  BY  THE  MANUFACTURER, 

OR  SOLD  WITH  THE  APPARATUS. 

WHEN A CART IS USED, USE CAUTION 

WHEN 

MOVING 

THE 

CART/APPARATUS  TO  AVOID  INJURY 

FROM TIP-OVER. 

Do not place this unit on an unstable cart, 

stand,  tripod,  bracket,  or  table.  The  unit 

may  fall,  causing  serious  injury  to 

someone,  and  serious  damage  to  the 

appliance.  A  unit  and  cart  combination 

should be moved with care.  

13. 

UNPLUG 

THIS 

APPARATUS 

DURING 

LIGHTNING 

STORMS 

OR 

WHEN  UNUSED  FOR  LONG  PERIODS 

OF TIME. 

For added protection for this unit during a 

lightning  storm,  or  when  it  is  left 

unattended and unused for long periods of 

time,  unplug  it  from  the  wall  outlet  and 

disconnect  the  antenna  or  cable  system. 

This  will  prevent  damage  to  the  unit  due 

to lightning and power line surges. 

14. 

REFER 

ALL 

SERVICING 

TO 

QUALIFIED 

SERVICE 

PERSONNEL. 

SERVICING  IS  REQUIRED  WHEN  THE 

APPARATUS  HAS  BEEN  DAMAGED  IN 

ANYWAY, SUCH AS WHEN THE POWER 

SUPPLY  CORD  OR  PLUG  IS  DAMAGED, 

LIQUID 

HAS 

BEEN 

SPILLED 

OR 

OBJECTS  HAVE  FALLEN  INTO  THE 

APPARATUS,  THE  APPARATUS  HAS 

BEEN 

EXPOSED 

TO 

RAIN 

OR 

MOISTURE, 

DOES 

NOT 

OPERATE 

NORMALLY, OR HAS BEEN FROPPED. 

15.  WARNING:  TO  REDUCE  THE  RISK 

OF  FIRE  OR  ELECTRIC  SHOCK,  DO 

NOT  EXPOSE  THIS  APPARATUS  TO 

RAIN OR MOISTURE. 

16. 

APPARATUS 

SHALL 

NOT 

BE 

EXPOSED 

TO 

DRIPPING 

OR 

SPLASHING  AND  NO  OBJECTS  FILLED 

WITH LIQUIDS, SHALL BE PLACED ON 

THE APPARATUS. 

 

Summary of Contents for V 10

Page 1: ...V SERIES USER S MANUAL ...

Page 2: ...ection Diagram 17 5 2 4 Pcc Advaced Software User s Manual 17 5 2 4 1 INSTALLATION 17 5 2 4 2 USING THE PCC CONTROLLER ADVANCED SERIES 17 5 3 RIGGING 25 5 3 1 Safety 25 5 3 2 Single V10 V12 V15 26 5 3 2 1 Flown Vertically 26 5 3 2 2 Mounted On a wall 26 5 3 2 3 On wind stand or on SW118 27 6 Contact 28 1 INTRODUCTION Thanks for purchasing TECNARE This product comprises the best quality designed to...

Page 3: ...chnology versions Self powered systems of high efficiency and low weight Systems individually DSP controlled by software in real time Graphical Equalizer of 30 bands by acoustic box Parametric Equalizer of 10 bands by acoustic box Individual control of gain solo and mute Individual Crossover of four bands Linkwitz Riley of 24dB octave Individual Compressor Limiter by band Variable delay on each ba...

Page 4: ...rsonnel 1 READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated 2 KEEP THESE INSTRUCTIONS The safety and operating instructions should be retained for future reference 3 HEED ALL WARNINGS All warnings on the product and in the operating instructions should be adhered to 4 FOLLOW ALL INSTRUCTIONS All operating and use of instructions should ...

Page 5: ...T IS USED USE CAUTION WHEN MOVING THE CART APPARATUS TO AVOID INJURY FROM TIP OVER Do not place this unit on an unstable cart stand tripod bracket or table The unit may fall causing serious injury to someone and serious damage to the appliance A unit and cart combination should be moved with care 13 UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME For added pro...

Page 6: ... these PCC speakers are linked by a network through a USB interface to the laptop Once connected we can control in real time the parameters of each speaker such as volume graphic equalisation parametic equalisation crossover internal delays compressor limiters check test save and recall of presets mute transfer spectrum analysis r t a spectrum control phase check and more Consisting of seven model...

Page 7: ...s Power Handling 520W nominal 1040W continuous Dimensions HxWxD 645x390x392mm Net weight 29 kg selfpowered Pcc version Components 1x12 LF driver 1x1 5 HF driver on a rotatable exponential horn V 15 Frequency Response 42Hz 17kHz 4dB Nominal Dispersion 80ºH x 60ºV 6Db Rotatable horn allows swap of horizontal and vertical pattern Impedance 8 Ohm Sensitivity 101dB 1w 1m Calculated max SPL 130dB Contin...

Page 8: ...The absolute latest in available technology is utilized with 64 bit floating point processors and high performance 24 bit Analogue Converters The high bit DSP prevents noise and distortion induced by truncation errors of the commonly used 24 bit fixed point devices A complete set of parameters include I O levels delay polarity 8 bands of parametric EQ per channel multiple crossover selections comp...

Page 9: ... 5 Rotary thumb wheel CH A Allows you to switch between presets To select the desire preset press the wheel 6 On SIGNAL CLIP led CH A When On indicates the unit is On Signal at the input and the input level is above the device s maximum headroom respectively 7 8 Ethernet connector Standard RJ 45 female socket 9 Power switch Controls power On Off 5 1 3 3 REAR PANEL FUNCTIONS 1 Main Power Connects v...

Page 10: ...V series User s Manual 10 28 5 1 4 V Series Recommended configurations ...

Page 11: ...V series User s Manual 11 28 ...

Page 12: ...V series User s Manual 12 28 ...

Page 13: ... recall of presets mute transfer spectrum analysis real time analyzer spectrum control phase check 5 2 1 Main Features Ethernet control 10 built in presets without the use of the software Unlimited presets storage in the PC Input graphic eq Parametric eq on each band 4 x 8 bands General Delay 4 band crossover Gain control Mute control Check test Buit in Analyzer Real time control Presets storage i...

Page 14: ...V series User s Manual 14 28 5 2 2 Back Panel Original Series ...

Page 15: ...V series User s Manual 15 28 Advanced Series ...

Page 16: ...V series User s Manual 16 28 Cobranet Series ...

Page 17: ...2 USING THE PCC CONTROLLER ADVANCED SERIES The Tecnare PCC Controller advanced series software application provides real time control and configuration editing for the DPA 28X using a laptop or other PC compatible computer In addition the application provides control over each individual input channel Gain Graphic EQ Compressor main delay and over each individual output channel Crossover 8 bands p...

Page 18: ... Load an existing preset from your computer Save Preset Save the current preset to a file Load Set Click this option to Load a Set of 10 preset from your computer Save Set Save the current set of 10 presets to a file Exit Exit the application CONNECT On line Connects the computer to the unit DELAY UNITS ms meter feet NETWORK WINDOW When the PC is connected to the unit the following information is ...

Page 19: ...he one on Red Double click to activate the unit By clicking on the group ID box the user will be able to assign each unit to a group SIGNAL GENERATOR By selecting active in the dropdown list a pink noise signal is generated by the 8 output channels The output level is controlled by the fader control INPUT LEVEL Main delay in ms meters or feet can be adjusted in this section The input level is adju...

Page 20: ...nal It is calibrated in decibels with a range from 40 0 dBu to 17 dBu Attack This determines how fast the compressor reacts once the threshold has been exceeded It is calibrated in milliseconds with a range from 1 ms to90 ms Release This determines how fast the compressor turns off once the signal falls below the threshold It is calibrated in milliseconds with a range from 10 ms to 2500 ms 2 5 sec...

Page 21: ...ifferent modes o Spectrum Analyzer o Transfer Function o Phase Response o Impulse Response Average Eight different time average can be selected 1 5 10 20 30 50 80 and 120 Window Signal Windowing by None Hamming Triangular Hanning and Blackman Smooth Is the frequency average None 1 3 1 6 1 12 1 24 Octave Input and Output Allows the user to choose the PC input and output device Pink noise Enable the...

Page 22: ...ible to visualize both signal simultaneously TRANSFER FUNCTION It shows the systems transfer function meaning the difference between the signal from the output of the DPA 28X to the microphone input signal PHASE RESPONSE It allows the user to analyze the phase response of an installation IMPULSE RESPONSE This tool provide the spectrum impulse response of a certain room NETWORK This button toggles ...

Page 23: ...te CROSSOVER This section contains two crossover filters per output Three different kinds of filters can be selected Bessel Butterworth L R The order of the filter can be selecting by pulling down the Bypass dropdown list Second Order filter 12dB Octave and Fourth Order filter 24dB Octave are available Filter cut off Frequency ranges from 20 to 20 000Hz in 1Hz steps PARAMETRIC EQ Eight bands param...

Page 24: ...o orange To copy the desire equalization to other output just click on Copy button go to the desire output parametric EQ and click on the paste button LIMITER Threshold The THRESHOLD controls are continuously adjustable from 40dBu maximum limiting to 17dBu Bypass Turn the module in bypass mode Attack Ranges from 0 1 to 90ms Release Ranges from 2x to 32x LEVEL DELAY Level The output level can be ad...

Page 25: ...at the system is secure and prevented from pivoting around the motor hoist NEVER use other item than Tecnare accessories When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall When deploying Tecnare Systems always wear protective headwear footwear and eye protection Ensure that all local and National regulations regarding th...

Page 26: ...lace the Double stud ring into the cargo restraint track 5 3 2 2 Mounted On a wall Items required LP_V10 LP_V12 LP_V15 L_V10 L_V12 L_V15 Procedure Remove the two up side screws from the box Place the LP_V accessory and secure it with 2 screws Hold the L_V10 L_V12 L_V15 to the wall Place the unit into the L_V accessory and secure it with two screws ...

Page 27: ...V series User s Manual 27 28 5 3 2 3 On wind stand or on SW118 Items required 1x Wind stand ...

Page 28: ...V series User s Manual 28 28 6 Contact Exel Acoustics S A Poligono Industrial Monte Boyal C Encinar 282 45950 Casarrubios del Monte Toledo Spain sales tecnare com Phone 34 918 170 110 Fax 34 918 183 053 ...

Reviews: