Button to return to the main screen.
Buttons to adjust the percentage of power that must be delivered by
the heating tool.
The heated surface's temperature is measured through the
temperature sensor built-into the tool. The maximum temperature the
sensor can measure is 240°C; if the object is heated to above this
temperature, the sensor will no longer provide the temperature reading
until the object's temperature drops to below 240°C.
In the event the surface subjected to infrared radiation is heated to
above 240°C, the temperature sensor built-into the tool will not be
damaged.
The precision in indicating the temperature of the object for
temperatures below 240°C is related to the calibration of the sensor
according to the surface to be heated.