Instruction manual
ITEM TE550
S.p.A.
2.7
- STEPPER MENU
-TE550 VER. 3.31--
PROGRAM DATA
SETUP MENU
>STEPPER MENU
This menu contains parameters associated with the current stepper operations.
STEPPER MENU
>TOTAL STEPS 3
SPOTS 1 04000
INCREMENT 1 12
%
In order to use this function, it is necessary that the electrodes dressing function (option with
board 50200) is disabled.
STEPPER MENU PARAMETERS TABLE
PARAMETER
PARAMETER DESCRIPTION
VALUE RANGE
TOTAL STEPS
Number of incremental steps
0 – 7
SPOTS 1
Spots step 1
00000 - 10000
INCREMENT 1
Percent increment step 1
00 - 60
SPOTS 2
Spots step 2
0001 - 5000
INCREMENT 2
Percent increment step 2
00 - 60
SPOTS 3
Spots step 3
0001 - 5000
INCREMENT 3
Percent increment step 3
00 - 60
SPOTS 4
Spots step 4
0001 - 5000
INCREMENT 4
Percent increment step 4
00 - 60
SPOTS 5
Spots step 5
0001 - 5000
INCREMENT 5
Percent increment step 5
00 - 60
SPOTS 6
Spots step 6
0001 - 5000
INCREMENT 6
Percent increment step 6
00 - 60
SPOTS 7
Spots step 7
0001 - 5000
INCREMENT 7
Percent increment step 7
00 - 60
TOTAL STEPS
This parameter indicates how many segments are to be created for implementing the stepper
curve. When it is set to zero, the stepper function is disabled.
SPOTS 1
This parameter indicates the number of spots of which the associated segment is composed.
When it is set to zero, the stepper function is disabled.
When TOTAL STEPS = 0 and SPOTS 1
≠
0, the value set in the SPOTS 1 parameter is equal
to the number of welding maximum spots.
INCREMENT 1
This parameter indicates the current stepper percentage to be attained upon the completing
of the spots set in the associated segment.
When it is set to zero, the stepper function is disabled.
36/92