BEFORE THE FIRST USE:

For safety reasons, the HU-P1316 hand strapping  

tool and the spare battery pack arrive discharged. 

Fully charge the batteries. 

1.  Pull the battery box cover up in the direction 

  of the arrow.

2.  When the battery is inserted, the current charging  

  status is briefly indicated by a colored LED light 

  on the top.

Remove discharged batteries and recharge them to make  

the device ready for use again.

If you use PP strapping, replace the internal spring with the 

enclosed one. See section „Adjustment of the welding pressure“ 

for this.

Color

Status

   Blue

Ready for use

   Red flashing 

Low battery power

   Red glow

Machine error

   Violet luminous

Work finished

LED STATUS INDICATION

OPERATING INSTRUCTIONS

WELDING TIME ADJUSTMENT 

1.  Adjust the welding time if the strapping melts too much  

  or the band does not hold.

2.  To do this, turn the right control clockwise to increase 

  the welding time.

ADJUSTMENT OF THE TENSIONING FORCE 

1.  Adjust the tensioning force if the strapping is too 

  loose or too taut.

2.  To do this, turn the left control clockwise to increase  

  the tensioning force.

Start with a low welding time and a low tension force and slowly approach the desired result to avoid damage to the  
fabric and injury from tearing straps.

Welding time

Tensioning force

Summary of Contents for HU-P1316

Page 1: ...Please read this manual before using the product and follow the instructions it contains OPERATING INSTRUCTIONS Battery hand strapping tool HU P1316 ...

Page 2: ...ONTENT Foreword 3 Safety instructions 3 Technical data 4 Main components 4 Operating instructions 5 Maintenance and repair 6 Troubleshooting 7 Packing and disposal 7 Warranty 7 GENERAL MAINTENANCE WARRANTY ...

Page 3: ...orized persons SAFETY INSTRUCTIONS Please read the instructions carefully failure to do so may result in injury during operation Only trained personnel may use this device Only use the strapping tool if you have a firm footing The device should not be used by mentally or physically impaired persons Only use high quality strapping tape that is suitable for this device Pay particular attention to wi...

Page 4: ...light 6 DC5 5 Socket 7 Power on toggle switch MAIN COMPONENTS Type Unit Value Size mm 340 x 130 x 118 Weight kg 3 2 Battery V Ah 12 4 Tension up to N 2800 Tensioning speed mm s 100 200 Strip width mm 13 16 Strip thickness mm 0 5 1 2 Usable strapping PET polyethylene PP polypropylene 1 2 6 7 3 4 5 ...

Page 5: ... Adjustment of the welding pressure for this Color Status Blue Ready for use Red flashing Low battery power Red glow Machine error Violet luminous Work finished LED STATUS INDICATION OPERATING INSTRUCTIONS WELDING TIME ADJUSTMENT 1 Adjust the welding time if the strapping melts too much or the band does not hold 2 To do this turn the right control clockwise to increase the welding time ADJUSTMENT ...

Page 6: ...e welding pressure is too low or too high this can lead to faulty welding This circumstance depends on 2 factors The material thickness and the strip material itself 1 Remove the battery from the housing of the device 2 Open the left cover of the housing by loosening the 3 M4 screws 3 Move the weld knob to the down position to expose the silver M6 nut above the tension spring 4 Tighten the nut to ...

Page 7: ...ACKING AND DISPOSAL PACKAGING The packaging and individual components are made of recyclable materials In detail these are PE polyethylene films and bags cardboard packaging We recommend keeping the packaging at least during the warranty period DISPOSE OF OLD EQUIPMENT OLD DEVICES MUST NOT BE DISPOSED OF WITH WASTE If the device can no longer be used every consumer is required by law to dispose of...

Page 8: ...V 16 08 21 TOPREGAL UK Ltd Carlton Drive Pen Y Fan Industrial Estate Crumlin Newport Gwent NP11 4EA 01495 707222 info topregal co uk www topregal co uk ...

Reviews: