Low Balance Than:
define the low balance value threshold
.
To apply the Low Balance Handle, it is required to configure the
Balance check properly; please refer to the FAQ of balance check for more details.
GSM Network side error code handle
When the gateway makes an outgoing call, GSM network side will respond a code which indicates the cause of the call of
failure; gateway will record these error codes until the gateway was restarted.
The error code 8, meaning of “Operator determined barring”, indicates precisely that the SIM was blocked by operator; so we
provide this feature to detect the error code and then blocked gateway module.
Follow these steps to use this feature:
a) Enable the error code record
The GSM network side error code record is disabled by default, you need to enable the record before you use this
feature.
Click “System Configuration” and “SIP Parameter”, then select “yes” for “GSM-Sip Code Map GSM Code Enable”.
Don’t forget to save the configuration.
b) Configure the GSM code monitor
By GSM Code
: The GSM network side error code
Counts of consecutive GSM Code
: The counts of the error code consecutively.
As the figure shows above, once the GSM error code 8 is detected, the gateway will blocked the gateway module.