                                                                                  TSR 2800-10C Hardware Installation Manual 

- 7 - 

ring. If there is no hand ring, use the metal clip with the metal cable to clip the unpainted metal part 

of the machine box. In this case, the static is discharged to the ground through the metal cable of 

the clip. You can also discharge the static to the ground through your body. 

2.3 Requirements for Common Locations 

This part describes the requirements for the installation locations. 

2.3.1 Environment 

The router can be installed on the desk or the cabinet. The location of the machine box, cabinet 

planning  and  indoor  cabling  are  very  important  for  normal  system’s  function.  Short  distance 

between devices, bad ventilation and untouchable control plate will cause maintenance problems, 

systematic faulty and breakdown.   

For  location  planning  and  device  locating,  refer  to  section  2.3.2  “Location  Configuration 

Prevention”. 

2.3.2 Location Configuration Prevention 

The following preventive measures assist you to design the proper environment for the router.   

 

Make  sure  that  the  workshop  is  well-ventilated,  the  heat  of  electrical  devices  is 

well-discharged and sufficient air circulation is provided for device cooling.     

 

Avoid  to  damage  devices  by  following  the  electrostatic  discharge  prevention 

procedure. 

 

Put  the  machine  box  at  the  place  where  cool  air  can  blow  off  the  heat  inside  the 

machine  box.  Make  sure  the  machine  box  is  sealed  because  the  opened  machine 

box will reverse the cool air flow. 

2.3.3 Cabinet Configuration 

The following content assists you to make a proper cabinet configuration:   

 

Each device on the cabinet gives off heat when it runs. Therefore, the sealed cabinet 

must have the heat-discharge outlet and the cooling fan. Do not put the devices too 

close, avoiding bad ventilation.   

 

When  you  install  the  machine  box  at  the  open  cabinet,  prevent  the  frame  of  the 

cabinet from blocking the airway of the machine box.   

 

Ensure that nice ventilation is provided for the devices installed at the bottom of the 

cabinet. 

Summary of Contents for TSR 2800-10C

Page 1: ...TSR 2800 10C Hardware Installation Manual...

Page 2: ...Requirements 8 2 4 Installation Tools and Device 8 Chapter 3 Installing the TSR 2800 10C Router 9 3 1 Installation Flow of TSR 2800 10C 9 3 2 Installing the Machine Box of the Router 9 3 2 1 Installin...

Page 3: ...et ports 10 100 1000M auto adaptation UTP RJ45 ports LINK ACT indicators Console port A rate of 9600bps RJ45 interface no indicator USB interface USB2 0 interface a rate of 1 5Mbps in low speed mode a...

Page 4: ...its corresponding indicators If the indicator is always on the link on the port is normal If the indicator flickers the data is received or transmitted through the port 7 USB USB interface 8 RST Reset...

Page 5: ...t BootRom 512K the patch design Standard configuration 2 gigabit Ethernet combo TX optical ports 8 gigabit Ethernet TX ports 1 Console port 1 USB interface 1 RESET key Packet forwarding rate 1Mpps Dim...

Page 6: ...TSR 2800 10C Hardware Installation Manual 4 AC power supply Input voltage 170 264V Input frequency 47 63Hz Input current 1A 230V 1 3 ROHS Description...

Page 7: ...ctive processing 2 2 Safety Advice 2 2 1 Safety Principles Keep dustless and clean during or after the installation Put the cover at the safe place Put tools at the right place where they are not easi...

Page 8: ...r line and tatty power line 2 Install the emergent on off at the working room for turning off the power when trouble happens 3 Turn off the power on off of the router and plug off the power line befor...

Page 9: ...iguration Prevention The following preventive measures assist you to design the proper environment for the router Make sure that the workshop is well ventilated the heat of electrical devices is well...

Page 10: ...provided in the phase line if you prepare the short circuit prevention measures for a building Caution If the power supply system does not have good grounding or the input power disturbs too much and...

Page 11: ...Caution Only professionals are allowed to install or replace the devices 3 1 Installation Flow of TSR 2800 10C 3 2 Installing the Machine Box of the Router The installation of the machine box has two...

Page 12: ...e installed install the router on the cabinet See the following figure 3 3 Connecting the Port 3 3 1 Connecting the Console Port TSR 2800 10C modularized router has one console port and one remote ass...

Page 13: ...hose pins can be aligned from left to right with the value from 1 to 8 Figure 3 1 Pin1 to Pin 8 Figure 3 2 Connecting the console port of TSR 2800 10C and computer Table 3 1 Pins of the console port N...

Page 14: ...800 10C The console cable is numbered as RLC0301 Figure 3 3 RLC0301 inner line connection 3 3 2 Connecting Gigabit Ethernet Ports TSR 2800 10C supports 8 10 100 1000M auto adaptation Ethernet TX ports...

Page 15: ...ormal phase of data 1 TP1 4 Sending receiving the paraphase of the data 1 TP1 5 Sending receiving the normal phase of data 2 TP2 6 Sending receiving the paraphase of the data 2 TP2 7 Sending receiving...

Page 16: ...Hardware Installation Manual 14 3 3 4 Connecting to the USB Interface The USB interface supports the physical layer protocol of USB2 0 The USB interface works in main mode which can be plugged into th...

Page 17: ...escribes how to open the cover of the router required tools and operation methods Caution When the power cable still connects the power supply do not touch it When you open the cover of the router you...

Page 18: ...cover and close the machine box Do as follows Put them well according to their locations and joint them together along their sides See the following figure When the cover and the bottom are closely t...

Page 19: ...k whether the fan works normally If the fan does not work well check the fan If the router is too hot check whether the air outlet and air inlet are clean and then do relative operations in section 2...

Page 20: ...yright Claims Without the written approval of the company any person or group cannot transcribe copy or change partial or all contents of this manual and must not broadcast it in any manner Trademark...

Reviews: