Refrigeration Chart
Normal Evaporator Range
Normal Condenser Range
Off Coil Air Temp
PSI
Outside Air Temp
PSI
26
15.69
53
110.20
28
17.04
54
112.10
30
18.43
55
114.10
32
19.87
60
124.30
34
21.35
62
128.50
36
22.88
64
132.90
38
22.47
66
137.30
40
26.10
68
141.90
42
27.79
70
146.50
44
29.52
72
151.30
46
31.32
74
156.10
48
33.17
76
161.10
50
35.07
78
166.10
52
37.03
80
171.30
54
39.05
82
176.60
55
40.09
84
182.00
60
45.48
86
187.50
65
51.27
88
193.10
70
57.47
90
198.90
75
64.10
95
213.70
80
71.19
100
229.40
85
78.75
105
245.80
90
86.80
110
263.00
95
95.40
115
281.10
100
104.40
120
300.10
101
106.30
125
320.00
102
108.20
130
340.80
Range show in
Bold
1
1
APPENDIX
c O m F O r t A i r e A / c s Y s t e m s
c c
8 0
Summary of Contents for ComfortAire
Page 5: ...lTechPlus s e r v i c e s u p p l e m e n t...
Page 50: ...49 1 APPENDIX C O M F O RT A IRE A C S Y STEMS c c 8 0...
Page 80: ...79 Notes n o t e s...
Page 81: ...lTechPlus s e r v i c e s u p p l e m e n t 80 Notes...
Page 82: ...81 Notes n o t e s...
Page 83: ...lTechPlus s e r v i c e s u p p l e m e n t 82 Notes...
Page 84: ...83 Notes n o t e s...