MasterCAN configuration with the service kit / Service MasterCAN software operation / MasterCAN settings
MasterCAN Vehicle Data Interfaces. Operation manual. Version 4.0
© Technoton, 2017
47
3.6.3 MasterCAN settings
Settings
area (see figure 25) provides the following options:
1) Output protocol type
2) MODBUS (DUTE-COM) address
to set network address for MasterCAN C 232/485 or
MasterCAN V-GATE when those are used as summators of DUT-E CAN fuel level sensors. By
default MasterCAN network address is equal to two last serial number digits;
3) FMS Messages Sending Permit
to enable/disable output of FMS messages by
MasterCAN
CC
or
MasterCAN
V-GATE
output
interface
4) Telematics Messages Sending Permit
to enable/disable output of Telematics
messages
by
MasterCAN
CC
or
MasterCAN
V-GATE
output
interface
5) CAN Request Permit
to enable/disable of sending requests into CANbus by input
interface of MasterCAN CC, MasterCAN C 232/485 or MasterCAN V-GATE. Active Requests
are used for gathering of the following information from automotive CANbus:
- engine operation time, RPMs;
ATTENTION
:
1)
Active requests sent into CANbus can cause malfunctions of vehicle equipment.
2)
Active requests sending is only possible for direct bus connections of
MasterCAN to CANbus. Requests cannot be sent when connecting with
contactless
6) J1708 Request Permit
— requests not transmitted to automotive J1708bus for current
version of software.
7) ASCII Message Interval, ms
used to set a time period for sending output messages
from MasterCAN C 232/485 or MasterCAN V-GATE according to ASCII standard (see
and
Interval can be set in range from 100 to 65535 ms (with 1 ms step). Default value
is 100 ms.