Type series 

Power

[Watt]

Dimensions

[cm]

Protection 

class

Special fea-

tures

TT-KS 2800 S

2800

158 x 63 x 7

IP 20

TT-KS 700 S LT*

700

  68 x 63 x 7

IP 20

about 60°C 

surface temper-

ature 

TT-KS 1200 S LT*

1200

 98 x 63 x 7

IP 20

about 60°C 

surface temper-

ature

TT-KS 1500 S LT*

1500

128 x 63 x 7

IP 20

about 60°C 

surface temper-

ature

TT-KS 1800 S LT*

1800

158 x 63 x 7

IP 20

about 60°C 

surface temper-

ature

TT-KS   500 S X4

500

  38 x 63 x 7

IP 24

TT-KS 1000 S X4

1000

  68 x 63 x 7

IP 24

TT-KS 1200 S X4

1200

  68 x 63 x 7

IP 24

TT-KS 1500 S X4

1500

  98 x 63 x 7

IP 24

TT-KS   800 N

800

  68 x 34 x 7

IP 20

TT-KS 1200 N

1200

   98 x 34 x 7

IP 20

TT-KS 1600 N

1600

128 x 34 x 7

IP 20

TT-KS 2000 N

2000

158 x 34 x 7

IP 20

TT-KS  800 N X4

800

  68 x 34 x 7

IP 24

TT-KS 1200 N X4

1200

  98 x 34 x 7

IP 24

TT-KS 1200 H

1200

 38 x 124 x 7

IP 20

TT-KS 1800 H

1800

55 x 124 x 7

IP 20

TT-KS 2200 H

2200

68 x 124 x 7

IP 20

TT-KS  1200 Hx4

1200

38 x 124 x 7

IP 24

HR 1200 KSB

1200

38 x 124 x 7

IP 24

*) See special Installation Instructions and Directions for Use  
OT = surface temperature is to be adjusted by an internal regulator

1) The dimensions marked with 

 1)

  are given for radiators in their complete state (i. e. with take-up? stirrups mounted on it)

S = Standard | N = Low | LT = low temperature | X4 = weatherproof protection

Summary of Contents for TT-KS 1200 S X4

Page 1: ...and Operating Instructions Electrical Partial Thermal Storage Heater Feet Castors Please read attentively and keep in a safe place Subject to alterations Id_no 911 360 9650 Issue 04 18 Ecological Design Directive 2015 1188 Feet castors This product is only suitable for well insulated rooms or for occasional use ...

Page 2: ...ur heaters is constantly supervised by a state accredited test centre This heater can be used by children aged from 8 years and above and by physically sensory or mentally restricted persons if they are supervised or given instructions on safe use and understand the hazards involved as it does not require any experience or knowledge This device is not a toy for children to play with Cleaning and u...

Page 3: ...room tem perature drops the room thermostat switches ON the heater again This process is repeated continuously as long as the heater is at the operation mode If you are going to be absent for a longer period of time please set the temperature to a lower level to save energy If you turn the control knob completely to the left the heater will be switched OFF 2 2 Installation with internal temperatur...

Page 4: ...cter than in dry rooms In addition to the already above mentioned provi sions of DIN VDE 0100 they have also comply with VDE 0100 701 Our bathroom radiators must be installed exclusively by an authorized and certified electrician All the instructions given in 3 1 shall be adhered to in full Exception Our bathroom heaters are additionally protected against expected moisture 4 Technical data Our sur...

Page 5: ... 24 TT KS 1200 S X4 1200 68 x 63 x 7 IP 24 TT KS 1500 S X4 1500 98 x 63 x 7 IP 24 TT KS 800 N 800 68 x 34 x 7 IP 20 TT KS 1200 N 1200 98 x 34 x 7 IP 20 TT KS 1600 N 1600 128 x 34 x 7 IP 20 TT KS 2000 N 2000 158 x 34 x 7 IP 20 TT KS 800 N X4 800 68 x 34 x 7 IP 24 TT KS 1200 N X4 1200 98 x 34 x 7 IP 24 TT KS 1200 H 1200 38 x 124 x 7 IP 20 TT KS 1800 H 1800 55 x 124 x 7 IP 20 TT KS 2200 H 2200 68 x 1...

Page 6: ...d the electric storage heater Remove the packaging Heed that no packaging residues stick on the heater Insert the rollers or feet from the bottom into the fins of the heater To ensure a secure standing pay attention to the same external distances 6 Report the case to the after sales service Your surface storage heater was carefully manufactured and checked repeatedly before dis patch If you should...

Page 7: ...of day YES Electronic temperature control in the room depending on the weekday NO Other control options multiple choice is possible NO Room temperature control with presence detection Room temperature control with detection of an opened window NO With remote control option NO With adaptive start control NO With limitation of heating time NO With a black lamp sensor NO 7 1 Tables Type TT KS S RF TT...

Page 8: ...indicative Pmin 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Manual thermal charge control with acknowledgement of the room inside and or outside temperature NO Maximum con tinuous thermal performance Pmax c 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Electronic charge control with acknowledgement of the room inside and or outside temperature NO Auxiliary current consumption Heating power supported with a fan NO At ...