3. Important safety instructions

3.1 Surface thermal-storage heaters for dry rooms

• 

The heaters should be only installed in accordance with the applicable provisions of DIN 

VDE 0100.  electrici  an improper function, disconnect the heater from the mains supply. 

Report the case to our customer service department as soon as possible.

• 

To  avoid  a  fire  hazard,  keep  the  following  safety  distances  when  mounting  the  heater:

 

 

From the each side wall of the heater to any masonry:   

 

 

5 cm

From the each side wall of the heater to flammable materials: 

 

 

10 cm

Distance from the heater to the floor:   

 

 

 

 

8 cm

Distance from the upper edge of the heater to the

building components or covers (e.g. window sills):  

flammable    

 

15 cm 

 

 

 

 

 

 

 

 

non-flammable  

10 cm

3.2 Bathroom heaters

• 

Statutory provisions applicable for use of electrical equipment in rooms with tubs or show-

ers are much stricter than in dry rooms. In addition to the already above-mentioned provi-

sions of DIN VDE 0100, they have also comply with VDE 0100-701. Our bathroom radiators 

must be installed exclusively by an authorized and certified electrician. All the instructions 

given in 3.1 shall be adhered to in full. Exception: Our bathroom heaters are additionally 

protected against expected moisture.

4. Technical data:

Our surface storage heaters are designed for protection class I and a mains voltage of 230V, 

50Hz. For all heater types listed in the table, internal electronic temperature regulators or re-

mote-controlled room temperature regulators are optionally available. Our various products of 

34 cm or 63 cm overall height are available in the IP24 version. All other heaters have protec-

tion class IP20. Please see the information given on the nameplate of the heater.

Type series 

Power

[Watt]

Dimensions

[cm]

Protection 

class

Special fea-

tures

TT-KS 500 S

500

  38 x 63 x 7

IP 20

TT-KS 1000 S

1000

  68 x 63 x 7

IP 20

TT-KS 1200 S

1200

  68 x 63 x 7

IP 20

TT-KS 1500 S

1500

  98 x 63 x 7

IP 20

TT-KS 1800 S

1800

  98 x 63 x 7

IP 20

TT-KS 2000 S

2000

128 x 63 x 7

IP 20

TT-KS 2400 S

2400

128 x 63 x 7

IP 20

Summary of Contents for TT-KS 1200 S X4

Page 1: ...and Operating Instructions Electrical Partial Thermal Storage Heater Feet Castors Please read attentively and keep in a safe place Subject to alterations Id_no 911 360 9650 Issue 04 18 Ecological Design Directive 2015 1188 Feet castors This product is only suitable for well insulated rooms or for occasional use ...

Page 2: ...ur heaters is constantly supervised by a state accredited test centre This heater can be used by children aged from 8 years and above and by physically sensory or mentally restricted persons if they are supervised or given instructions on safe use and understand the hazards involved as it does not require any experience or knowledge This device is not a toy for children to play with Cleaning and u...

Page 3: ...room tem perature drops the room thermostat switches ON the heater again This process is repeated continuously as long as the heater is at the operation mode If you are going to be absent for a longer period of time please set the temperature to a lower level to save energy If you turn the control knob completely to the left the heater will be switched OFF 2 2 Installation with internal temperatur...

Page 4: ...cter than in dry rooms In addition to the already above mentioned provi sions of DIN VDE 0100 they have also comply with VDE 0100 701 Our bathroom radiators must be installed exclusively by an authorized and certified electrician All the instructions given in 3 1 shall be adhered to in full Exception Our bathroom heaters are additionally protected against expected moisture 4 Technical data Our sur...

Page 5: ... 24 TT KS 1200 S X4 1200 68 x 63 x 7 IP 24 TT KS 1500 S X4 1500 98 x 63 x 7 IP 24 TT KS 800 N 800 68 x 34 x 7 IP 20 TT KS 1200 N 1200 98 x 34 x 7 IP 20 TT KS 1600 N 1600 128 x 34 x 7 IP 20 TT KS 2000 N 2000 158 x 34 x 7 IP 20 TT KS 800 N X4 800 68 x 34 x 7 IP 24 TT KS 1200 N X4 1200 98 x 34 x 7 IP 24 TT KS 1200 H 1200 38 x 124 x 7 IP 20 TT KS 1800 H 1800 55 x 124 x 7 IP 20 TT KS 2200 H 2200 68 x 1...

Page 6: ...d the electric storage heater Remove the packaging Heed that no packaging residues stick on the heater Insert the rollers or feet from the bottom into the fins of the heater To ensure a secure standing pay attention to the same external distances 6 Report the case to the after sales service Your surface storage heater was carefully manufactured and checked repeatedly before dis patch If you should...

Page 7: ...of day YES Electronic temperature control in the room depending on the weekday NO Other control options multiple choice is possible NO Room temperature control with presence detection Room temperature control with detection of an opened window NO With remote control option NO With adaptive start control NO With limitation of heating time NO With a black lamp sensor NO 7 1 Tables Type TT KS S RF TT...

Page 8: ...indicative Pmin 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Manual thermal charge control with acknowledgement of the room inside and or outside temperature NO Maximum con tinuous thermal performance Pmax c 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Electronic charge control with acknowledgement of the room inside and or outside temperature NO Auxiliary current consumption Heating power supported with a fan NO At ...

Reviews: