Technotherm PH SlimLine Instruction Manual Download Page 5

Instruction Manual -   PH Slimline

Feel good through warmth from electricity - www.technotherm.de

GB

|5

5. PROGRAMMING WEEKLY

Select the mode with the keys of displacement

When you enter in the Program mode, the first operation is to choose the program number using the

 (-) or (+) keys. You can choose between a built-in program P1 to P9 or an user program U1 to U4. Select a 

program and press ok to validate.

If you select a built-in program P1 to P9, you can view and select only one of the following pre-set program 

options.

 

P1: Morning, Evening & Weekend

 

P2: Morning, Midday, Evening & Weekend

 

P3: Day & Weekend

 

P4: Evening & Weekend

 

P5: Morning, Evening (Bathroom)

 

P6: Morning, afternoon & Weekend

 

P7: 7H – 19H (Office)

 

P8: 8H – 19H & Saturday (Shop)

 

P9: Weekend (Secondary house)

The bars indicate the hours with comfort temperature and the rest of the day the spaces represent the eco

(reduced) temperature mode. (See the appendix section to view a complete description of the Built-in 

program)

• 

Use the navigation key right (     ) to view the program of alternative days of the week.

• 

Press the (OK) key to confirm your choice and return to the main screen (in AUTO mode)

• 

If you select a user program U1 to U4 as mentioned above you can choose the program, view it and also 

amend it.

Default setting:

• 

U1, U2, U3, U4 = in comfort for the week

• 

Press the confirmation key (OK) to customise a user program

Description of the creation of a user program:

• 

The program step is 30 minutes

• 

Each time a value or icon blinks you are

      invited to make a choice with the (-) or (+)

     keys. Once the choice is made press the (OK) key 

     to jump to the following step.

Day

Program of the day

Program number

Summary of Contents for PH SlimLine

Page 1: ...y www technotherm de 1 Model PH Slimline Instruction Manual PH SlimLine THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 401 Edition 01 18 ...

Page 2: ...he aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understand the risks All children under 8 y...

Page 3: ...rst move the square cursor on the clock mode then press the key or to start the adjust ment Each time a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monda...

Page 4: ... the Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current settingntemperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will eturn when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the u...

Page 5: ...Shop P9 Weekend Secondary house The bars indicate the hours with comfort temperature and the rest of the day the spaces represent the eco reduced temperature mode See the appendix section to view a complete description of the Built in program Use the navigation key right to view the program of alternative days of the week Press the OK key to confirm your choice and return to the main screen in AUT...

Page 6: ...able in all modes FUNCTION WINDOWS OPEN This function will stop the radiator automatically when it detects a window open if the radiator is running When this feature is enabled the icon appears at the top left of the screen If the system detects a fall of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the radiator Pressing ...

Page 7: ...perature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram This automatic control system works in the following way When you start your thermostat for the first time it will measure the time taken by your installation to reach the set temperatur...

Page 8: ... 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem on the regulation sensor the regulation will be replaced by a rate of 5 functioning The logo and the text Err blinks Error detec...

Page 9: ...rmal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the v...

Page 10: ...e a plug on the supply cord installation should be carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of the country where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the rated values ind...

Page 11: ...y problem occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire hea...

Page 12: ... 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stages...