2.1 Technical data 
 

 

 
 

Model 

Power [W] 

Dimensions (ill.) 

    a [mm]                    b [mm]                     weight [kg] 

CPH 1000 

1000 

415 

215 

4,8 

CPH 1500 

1500 

565 

365 

6,0 

CPH 2000 

2000 

695 

495 

7,0 

CPH 2400 

2400 

915 

715 

8,2 

 
 

2. 2 Operation 
 

Connect the heating convector to the mains supply 
to set it into operation. 

 
Switching the appliance on 

 
Switch on the appliance by setting the tumbler switch 
to position „1“. 

 

Switching the heating on 
 

Switch on the heating by turning the temperature selector switch and choose the required temperature. 
The temperature range extends from 4°C to 40°C  graduated into 10 steps. The thermostat switches  off 
the heating as soon as the preset ambient temperature  is reached, which will then be kept constant  by 
cyclic heating. The high consistency of the thermostat (below 2 K) provides a constantly comfortable 
temperature and thus ensures power-saving heating. 

 
Anti-freezing protection 

 
When setting the temperature selector switch to  grade „1“ the thermostat automatically cuts in if the 
ambient temperature falls below 4°C. 

 
Switching the appliance off 

 
Switch off the appliance by setting the tumbler switch to position „0“. 
 

3. Important notes 
 

During operation the temperature at the front panel  and at the hot-air outlet of the convector may rise 
above 85 °C. Do not place any objects on or beside the heater, do not put anything between the heater 
and the wall. Free air exit must not be hindered by covering the hot-air outlets with any objects such as 
curtains, pieces of laundry etc., otherwise risk of overheating. Combustible objects such as wood, paper, 
textiles  etc. as well as highly flammable substances such  as wax, petrol, aerosols must not be  placed 
near  the heater within the hot-air current. Switch the  heater off when carrying out work where highly 
flammable vapors could emerge, such as laying  or sealing parquet or other kinds of floor covering  or 
when using aerosols, floor wax, petrol etc. 
 
 

 

GB 

Summary of Contents for CPH 1000

Page 1: ...ONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Edition 01 14 Id Nr 911 360 860 Installation and technical manual Panel Heater CPH 1000 2400 GB ...

Page 2: ...ools In case the connection cable is damaged it has to be replaced by the manufacturer or someone commissioned by the manufacturer WARNING Do not use a switching oriented device like a timekeeper when operating this heater This could cause a change in the thermal adjustment which is potentially hazardous To keep the device from overheating do not put towels or clothing on top When using the heater...

Page 3: ...power saving heating Anti freezing protection When setting the temperature selector switch to grade 1 the thermostat automatically cuts in if the ambient temperature falls below 4 C Switching the appliance off Switch off the appliance by setting the tumbler switch to position 0 3 Important notes During operation the temperature at the front panel and at the hot air outlet of the convector may rise...

Page 4: ...y room size The convector comes complete with connecting cable that must be connected to a wall socket The appliance has been designed to be connected to 230V alternating current AC Fixing Fix the appliance in such way that any potentially combustible objects cannot catch fire Therefore the minimum safety distances mentioned below must be kept Fix the heater to an upright wall that is resistant to...

Page 5: ...ecessary to install a connector socket for fixed connection where the connecting cable of the appliance H05 VVF 3 x 1 0 mm2 power class 1000 W H05 VVF 3 x 1 5 mm2 power class 1500 W 2400 W Permanent cables must not be connected directly to the appliance If the electrical installation is done by means of an isolating unit it should be taken care that the isolation is designed with at least 3 mm sep...

Page 6: ...Diagram of connections Lucht LHZ Elektroheizung GmbH Co KG Obere Hauptstr 61 D 09232 Hartmannsdorf Fon 49 0 3722 63370 Fax 49 0 3722 633720 E mail info technotherm com Web www technotherm com TECHNOTHERM Support Fon 49 0 911 937 83 210 GB ...

Reviews: