2.5. Electrical Specifications
All parameters measured under the following conditions (unless otherwise specified):
T
amb
= 0…40
°
C, V
LOG
= 24 V
DC
; V
MOT
= 48V
DC
; Supplies start-up / shutdown sequence: -
any-
Load current (sinusoidal amplitude / continuous BLDC,DC,stepper) = 8A iPOS4808
Operating Conditions
Min.
Typ.
Max.
Units
Ambient temperature
0
+40
ºC
Ambient humidity
Non-condensing
0
90
%Rh
Altitude / pressure
Altitude (referenced to sea level)
-0.1
0 ÷ 2.5
2
Km
Ambient Pressure
0
2
0.75 ÷ 1
10.0
atm
Storage Conditions
Min.
Typ.
Max.
Units
Ambient temperature
-40
TBD
ºC
Ambient humidity
Non-condensing
0
100
%Rh
Ambient Pressure
0
10.0
atm
ESD capability (Human body
model)
Not powered; applies to any accessible part
±
0.5
kV
Original packaging
±
15
kV
Mechanical Mounting
Min.
Typ.
Max.
Units
Airflow
natural convection
, closed box
Spacing required for vertical
mounting (see
Between adjacent drives
30
mm
Between drives and nearby walls
30
mm
Between drives and roof-top
20
mm
Spacing required for horizontal
mounting (see
Between adjacent drives
4
mm
Between drives and nearby walls
5
mm
Space needed for drive removal
10
mm
Between drives and roof-top
15
mm
Insertion force
Using recommended mating connectors
31
55
N
Extraction force
8
16
N
1
Operating temperature at higher temperatures is possible with reduced current and power ratings
2
iPOS480x can be operated in vacuum (no altitude restriction), but at altitudes over 2,500m, current and power rating are
reduced due to thermal dissipation efficiency.
3
In case of forced cooling (conduction or ventilation) the spacing requirements may drop down to mechanical tolerances
as long as the ambient temperature is kept below the maximum operating limit