4.3. Changing the drive Axis ID
The axis ID of an iPOS4808 drive can be set in 3 ways:
Hardware (H/W) – according with AxisID hex switch SW1 par. 3.4.2 .
Software (via Setup)– any value between 1 and 255, stored in the setup table. If the drive
is in CANopen mode, a Node ID value above 127 is automatically converted into 255 and
the drive is set with CAN communication in “non-configured” mode waiting for a CANopen
master to configure it using CiA-305 protocol. A “non-configured” drive answers only to
CiA-305 commands. All other CANopen commands are ignored and transmission of all
other CANopen messages (including boot-up) is disabled. In absence of a CANopen
master, you can get out a drive from “non-configured” mode, by setting another axis ID
between 1 and 127, from above dialogue using a serial link between the drive and the PC.
Software (via CANopen master) – using CiA-305 protocol
The axis ID is initialized at power on, using the following algorithm: