background image

 

Mini-Line G198 operating manual

 

Page 9 

Technical specifications Mini Line

®

 G198 

 

 

 

Mini Line® G198 

Input voltage 

8...30vdc 

Input current 

40mA 

Output voltage 

couple with i/p 

Output current 

1,2A 

Operating temp. 

0-70 °C 

Storage temp. 

-40 °C - 85 °C 

Protection 

short cct/rvs polarity 

Vertical align. 

±40mm 

Sensitivity ctrl. 

5.0 

Deadband ctrl. 

1mm 

Working range 

65 - 195mm 

Working window 

±25mm 

Pwm 

20ms 

Null position 

144mm 

Weight 

1kg approx. 

Colour 

Mat black 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mini-Line® G 198 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUR-S 4x0,75 + 2x0,25mm

 

 

 

 

 

 

 

 

CA06COM-E18S-1S 

 

 

 

 

 

 

 

 

 

CA3106E14S-6S-B 

Connector/Plug 

  CA3102E14S-6P-B  CA3106E14S-6S-B  CA06COM-E18S-1S 

8...30VDC 

8...30VDC 

Ground 

Ground 

Ground 

8...30VDC 

Pulse (up) 

Pulse (up) 

Pulse (up) 

Pulse (down) 

Pulse (down) 

Pulse (down) 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/A 

N/A 

N/C 

N/A 

N/A 

N/C 

N/A 

N/A 

N/C 

N/A 

N/A 

N/C 

Outer 

sheath

 

Diameter: 

7,5mm 

Colour: Yellow 

 

Cabling

 

4 cores 

0,75mm2 

1 pair 0,25 mm2 

 

Conductor

 

Finely stranded 

Cu wire 

Class 6 

 

Insulation

 

Thermoplastic 

polyurethane 

Hardness:87 

shore A 

 

weight 

Cu content: 

35kg/km 

PVC content: 

0kg/km 

Gross weight: 

67kg/km 

Electric 

data 

DC resistaNCE: 

26,0/km at 20°C 

 

 

Summary of Contents for Mini Line G198

Page 1: ...Mini Line G198 operating manual Mini Line G198 Mechanical Grade Control User Manual V G704301 Please read carefully before installation...

Page 2: ...8 2633 Email sales tf technologies com www tf technologies com Product verification Verify for damages to equipment due to transportation In case of any damage or equipment malfunctioning contact supp...

Page 3: ...try 2 Microprocessor unit 3 Power driver circuit Any linear displacement is accurately and quickly transformed into digital signal and after being analyzed and compared with the reference point inform...

Page 4: ...fulfilled and have excellent low temperature characteristics The coiled cable is yellow in colour and delivers in standard length of 4 0 m when fully uncoiled The standard coiled cable consists of 2...

Page 5: ...isher operation manual for further information on machine power control box Note Depending on user s ability installation of the mechanical sensor parts G198 Grade Control and cable connections may ta...

Page 6: ...red Asphalt Paver Requirements A pre condition for the safe use of Mini Line Grade Control System in accordance with applicable safety regulations is that the system is only used on asphalt pavers tha...

Page 7: ...uations and be able to avoid them Be aware of the specifications of the G198 to ensure that they are working properly See Technical Specifications data sheets Responsibility of the Operator When plann...

Page 8: ...same time It is not recommended to adjust the screed manually on the built in panel on the asphalt paver while G198 is in auto mode or by use with HS301 where this is in auto mode as the system will...

Page 9: ...ommence repair Precautions Inspect cables regularly for evidence of wear or deterioration Inspect the receptacles and cable connectors for damages dirt or water Caution Deposits of dirt grease and asp...

Page 10: ...ack Mini Line G 198 PUR S 4x0 75 2x0 25mm2 CA06COM E18S 1S CA3106E14S 6S B Connector Plug CA3102E14S 6P B CA3106E14S 6S B CA06COM E18S 1S A 8 30VDC 8 30VDC Ground B Ground Ground 8 30VDC C Pulse up Pu...

Page 11: ...ble to the failure of the equipment TF Technologies liability being specifically limited to repair as stated hereinabove This warranty is automatically initiated except where modified by contractual o...

Reviews: