Initial operation
Open the Weather Station battery compartment cover
Insert 2 x AA batteries observing polarity [ “+” and “ –“ marks]
When you insert the batteries, all icon on the LCD will light up for 3 seconds, and you will
hear a beep tone, then detect indoor temperature & humidity.
The Weather Station will now start to make a connection to the outdoor remote sensor.
This operation takes about 3 minutes and will displayed by a flashing reception RF
antenna symbol in the “OUTDOOR” display area on the receiver.
This now, Open the remote sensor battery compartment cover, Insert 2 x AA batteries
observing polarity [ “+” and “–“ marks]
After receiver has created a connection to the outdoor remote sensor, After 3 minutes it
will enter the
DCF
Radio control time receive mode.
Reception of the Radio signal
The weather station will enter DCF77 signal reception after receiving outdoor temperature
or 3 minutes after start up.
At 1:00 /2:00 / 3:00 AM, the clock automatically carries out the synchronization procedure
with the
DCF
signal to correct any deviations to the exact time. If this synchronization
attempt is unsuccessful (the radio mast icon disappears from the display), the system will
automatically attempt another synchronization at the next full one hour. This procedure is
repeated automatically up to total 5 times.
To start manual
DCF
signal reception, press and hold
the “
Wave
” buttonB3 for 2 seconds.
If no signals received within 7 minutes, then the
DCF
signal search stops (the radio mast
icon disappears) and start again at the next full one hour.
During DCF77 reception, to stop searching radio signal, press the
“
Wave
” buttonB3 once.
Notes:
A flashing radio mast icon indicates that the
DCF
signal reception has started
A continuously displayed radio mast icon indicates that the
DCF
signal was received
successfully
We recommend a minimum distance of 2.5 meters (8.2Feet) to all sources of interference,
such as televisions or computer monitors or switching power adapter.
Radio reception is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In
such extreme circumstances, place the system close to the window.
During the RC receive mode, only the "
Light
" B5 and
“
Wave
”B3 buttons have a
function, other buttons are not functional. If you want to use all functions, please press
“
Wave
” button to exit the
DCF77
reception.
Manual time setting
In normal mode, press
SET
button to switch display date/ alarm time/ second.
IN date or second mode, press and hold the
SET
button for 3 seconds, into the setting
mode, the set item will blink disp lay. Press
“
+
” or “
-
” buttons to adjustment the value,
Press
SET
button to confirm the item has been set and go to the next one, the sequence
of setting items is as follows: