42
When the remote channel temperature value exceeds the set temperature range, the temperature alarm will sound,
at the same time the temperature
alarm icon “ ” flashes, its temperature value and alarm upper limit icon “Hi” or
lower limit icon “Lo” also flashes.
When the temperature of outdoor sensor is
–1°C (+30°F) to + 3°C (+ 37°F), the frost alarm will be activated, the frost
alert icon “ ” flashing. The frost alarm acts independently from active or inactive temperature alarm.
Notes:
When the temperature is higher than the upper limit of the alarm temperature setting, the activation of the upper limit
alarm, symbol “Hi” flashing,
When the temperature is lower than the lower limit of the alarm temperature, the lower limit alarm is activated, and
the symbol “Lo” flashes
Low battery:
If the battery icon “
” appears the batteries in the outdoor sensor should be replaced as soon as possible.
The weather forecast:
The weather station calculates a weather forecast for about the next 12 hours based on the barometric pressure