TKLS • USER MANUAL

21

TechnoKom © 2014

•  To start auto calibration, press the Start calibration tab. The pump will start fuel transition 

from the storage tank into the fuel tank. The current state of the pump is displayed on the 

Auto calibration tab – Pump is turned off, Pump is turned on. If the calibration has not started, 

check the frequency output mode and ensure that the Auto calibration mode is selected on 

the Settings tab (see Fig.1);  

•  While calibration, calculated calibration points are added in the calibration table on the 

Auto calibration tab. Current readings of the TKLS sensor are displayed at the top of the 

table – current fuel level in liters, appropriate sensor readings in the form of ADC stages and 

frequency;

• 

The target-liters display fuel level achieving which starts next step of calibration; 

• 

The performance displays fuel volume transferred by the pump per a minute;

•  When the calibration is on, the status “Calibration” is displayed on the status bar (at the 

bottom of the window);

Fig.4.Calibration finished.

The calibration is totally managed by the TKLS sensor. It means that after starting the calibration 
the configuration tool can be closed and opened to read complete calibration data after finishing the 
calibration.  

i

NOTE

IMPORTANT

Calculated calibration table is stored in the sensor memory till the sensor power restart. That’s way it is 
not recommended to restart the sensor after finishing the calibration till the calibration data will be read 
from the sensor.  

•  To pause the calibration, press the 

Pause button. To cancel the calibration, 

press the Stop button (displayed instead of 

the Calibration button when the calibration 

is on);

•  As all calibration points have been 

calculated, the calibration finishes (Fig.4). 

After that the calibration table can be saved 

in  an  external  file  by  pressing  the  Save 

calibration button. The calibration table is 

saved in text file in the \Tare folder located 

in root directory of the configuration tool.

Summary of Contents for TKLS

Page 1: ...TKLS USER MANUAL 1 TechnoKom 2014 FUEL LEVEL SENSOR USER MANUAL DOCUMENT VERSION 1 11...

Page 2: ...echnical Specification 6 Scope of Supply 8 Components of Sensor 9 Interface Connectors 10 Getting started 11 Sensor Connection 15 Power Supply Connection 16 RS 485 TIA EIA 485 A Bus Connection 17 Freq...

Page 3: ...en the AutoGRAPH Series on board vehicle tracking controllers and the TKLS fuel level sensors AutoGRAPH Hardware Interface Protocol is considered to be confidential information and intellectual proper...

Page 4: ...systems as a whole as well as understanding the functions of its individual components Introduction IMPORTANT All information on functions functional capabilities and other specifications related to T...

Page 5: ...ed fuel level PWM signal or periodic sequence In addition to fuel level the sensor measures ambient temperature and sends the readings to an external device Any device equipped with RS 485 which suppo...

Page 6: ...485 Yes Remote Firmware Update Yes Logging Yes Temperature Measuring2 Yes Digital Input numbers 1 Frequency Output Output Frequency Range Hz 100 3000 Output Type Open collector Maximum Load Current mA...

Page 7: ...nthecontrollerasitisenabledintheTKLSbydefaultand doesnotrequireanysensorre configuration Itmeansthatifthedevice whichtheTKLSisconnectedto initiatesthecommunicationintheAGHIPprotocol thesensorwillautom...

Page 8: ...icate 1 pc Scope of Supply Themountingkitincludesfollowingtools Sealgasket 1pc Self tappingscrewswithmountedwasherandsealing M5size 5pc Rivetnut knurled M5size 5pc Machinescrew M5size 5pc Plasticseal...

Page 9: ...orcover 5 Sealgasket 6 Measuringprobe 7 Endcap2 8 Sealinghole x4 1Devicedesignationcontainstrademarkandcontactdetailsofthemanufacturer devicedescription serialnumberandreleasedateofthedevice 2Thesenso...

Page 10: ...nge RS 485 A 3 Gray Frequency output 4 Black Vin 5 Brown RS 485 B 6 White Digital input active low InterfaceConnector1 male Viewfromsideofpins Connector2 female Viewfromsideofsockets Thisistheconnecto...

Page 11: ...to install the sensor as shown above it should be located as close as possible to the recommended area If due to the geometric features of the tank one fuel level sensor does not provide the required...

Page 12: ...5 bolts Install the seal gasket on the sensor then mount the sensor into the tank Cut the sensor length The sensor length can be cut to match the specific fuel tank To do this you should follow these...

Page 13: ...must be removed from fuel tank and the measuring tubes must be cleaned from fuel residues e g let the fuel drain off the tubes for about 15 20 minutes after the sensor removing from fuel tank Tosetan...

Page 14: ...or this application if the sensor is calibrated by inserting into a fuel storage first turn the sensor upside down and pour about 10 20 ml of fuel into the measuring probes through the drain hole e g...

Page 15: ...stipulated by the regulations for motor vehicle repair procedures All connections should be properly isolated and securely connected If the wire is too short it can be spliced with a wire of at least...

Page 16: ...g which should be cut before operation The power supply input of the sensor is rated for a voltage of 7 60 V To connect the power to the sensor you should follow these steps Connect Vin wire of the si...

Page 17: ...gured in the configuration tool TKLS sensor can be connected to following devices via RS 485 bus AutoGRAPH on board vehicle tracking device Communication can be provided in AGHIP LLS and Modbus protoc...

Page 18: ...er inputs1 4 The frequency output is intended for connection to the digital input of the AutoGRAPH on board vehicle tracking device which can acquire the reading in frequency form to digital input of...

Page 19: ...If difference between adjacent readings does not exceed the acceptable deviation the last reading is added in the calibration table in the form of ADC stages and frequency along with actual fuel leve...

Page 20: ...chnical documentation on the flowmeter Also set up acceptable deviation and timeout between sensor adjacent readings Then apply settings by pressing OK button and go to the Auto calibration tab Before...

Page 21: ...per a minute When the calibration is on the status Calibration is displayed on the status bar at the bottom of the window Fig 4 Calibrationfinished The calibration is totally managed by the TKLS senso...

Page 22: ...nd LLS protocols The code is recorded in the controller as a temperature record Error Code Description Error Code Error failure description 127 short circuit 126 capacitance probe break 125 frequency...

Page 23: ...he Drivers section To connect the sensor to a PC use TKLS Prog 485 USB RS485 converter see fig 5 The converter is supplied with the adapter intended to connect the converter to TKLS L sensor Fig 6 Con...

Page 24: ...bsite of TechnoKom The AGUSB Driver is compatible with MS Windows 7 8 Server 2003 Server 2008 x86 x64 To install the driver Connect the sensor to a PC The system will automatically search for a new eq...

Page 25: ...ation high bit 0x06 Zero calibration low bit 0x07 Averaging time weighting coefficient 0x08 Temperature 0x09 Raw fuel level data high bit 0x0A Raw fuel level data low bit 0x0B Fuel level 0x0C Serial n...

Page 26: ...TKLS USER MANUAL 26 TechnoKom 2014 Appendix APPENDIX 1 SAE 5 MOUNTING APPENDIX 2 BUILD IN ACCELEROMETER AXES ORIENTATION...

Page 27: ...TKLS USER MANUAL 27 TechnoKom 2014 Copyright Chelyabinsk 2016 All Rights Reserved www tk nav com info tk nav com TechnoKom ltd FUEL LEVEL SENSORS...

Reviews: