• To start auto calibration, press the Start calibration tab. The pump will start fuel transition
from the storage tank into the fuel tank. The current state of the pump is displayed on the
Auto calibration tab – Pump is turned off, Pump is turned on. If the calibration has not started,
check the frequency output mode and ensure that the Auto calibration mode is selected on
the Settings tab (see Fig.1);
• While calibration, calculated calibration points are added in the calibration table on the
Auto calibration tab. Current readings of the TKLS sensor are displayed at the top of the
table – current fuel level in liters, appropriate sensor readings in the form of ADC stages and
frequency;
•
The target-liters display fuel level achieving which starts next step of calibration;
•
The performance displays fuel volume transferred by the pump per a minute;
• When the calibration is on, the status “Calibration” is displayed on the status bar (at the
bottom of the window);
Fig.4.Calibration finished.
The calibration is totally managed by the TKLS sensor. It means that after starting the calibration
the configuration tool can be closed and opened to read complete calibration data after finishing the
calibration.
i
NOTE
IMPORTANT
Calculated calibration table is stored in the sensor memory till the sensor power restart. That’s way it is
not recommended to restart the sensor after finishing the calibration till the calibration data will be read
from the sensor.
• To pause the calibration, press the
Pause button. To cancel the calibration,
press the Stop button (displayed instead of
the Calibration button when the calibration
is on);
• As all calibration points have been
calculated, the calibration finishes (Fig.4).
After that the calibration table can be saved
in an external file by pressing the Save
calibration button. The calibration table is
saved in text file in the \Tare folder located
in root directory of the configuration tool.