Page 7.15
7.13. DISASSEMBLING THE PLATFORMS WITH CSAFE BOARD
CONNECTORS AND POWER ENTRY MODULE
Figure 7.13-1
The front and rear platforms house the following
components:
•
connector of the cable leading to the CSafe
board (front platform, on the right in the
figure);
•
Power entry module (rear platform, on the
left in the figure).
1. To access the connectors, turn the machine
over on one side.
2. Back off the screws
a
of the platform which
houses the desired connector, using a
medium Phillips screwdriver.
Figure 7.13-2
At this point it is possible to:
3. Unplug connector
b
of the cable which goes
up to the CSafe board.
4. Back off the two screws
c
and remove the
Power entry module.
Continued on following page
→