JOG NOW : Service & maintenance manual - rev. 5.1
Page 6.34
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check the correct display SW version, according to the “EXCITE SW SMART TABLE” you
can find in
TG Direct
section.
(2)
Check if the receiver has been correctly mounted on the machine, as detail at paragraph: 7.6.2.
(3)
Place the tester probes across pins
1
and
2
on
HD4
connector of receiver. The measured value
should be +5Vdc.
(4)
As at step
(3)
but on pin
1
and
8
on
CN9
connector of
CU141
cable
(
ARM Board
)
.
If you replace CPU/ARM Board, check that its SW version is updated, otherwise install
the last version.