34
After removing the piston from the faucet body, clean using the cleaning device provided.
⇒
CLEANING OPERATIONS
1)
Wash all the disassembled parts in hot water (50°C) with detergent (e.g.
DIVER SEY – SU891
available
in Italy or
DIVER SEY – VK3L
available in other countries)
using a concentration of the product
between 5
÷
10%
.
2)
Use the three-bowl sink to wash, rinse and sanitize all the disassembled parts. For sanitizing use acid
(e.g.
Percitric
or
Peracetic
) so as to obtain a final concentration of
0,1
÷
0,3%
in cold water, max
25°C, to sanitize the parts. Leave the parts to soak in the sanitizing solution for five minutes (no more
than fifteen). Leave the parts to dry naturally on the draining board,
without using sponges or tea-
towels.