C:\Documents and Settings\mconti.TECHNOGEL-USA\My Documents\MACCHINE\ARTESAN\ART
MANUALS\Mantegel\Inglese\MG 2V Istruzioni Inglese 01-08.doc
61
MANTEGEL 30
AIR
- technical specifications
Refrigerator compressor
Semi-airtight HP 2 (KW 1,5)
Refrigerating gas
Freon R404A (quantity 1,2 Kg.)
Condenser Ventilators
N° 2
– 220V monophase kW 0,135 cad.
Condensation
AIR
Overload cutout calibration
V.200
50/60HZ
V.220
50HZ
V.220
60HZ
V.400
50HZ
V.380
60HZ
V.415
50HZ
Compressor
A.
9,5
9,5
5,5
Dasher motor:
- low velocit y
A.
- high velocit y
A.
8,5
13,5
9
13
5,5
9
Elettrical fuse
V.200 e V.220
V.380 e V.415
Line protection
n° 3 d. 10 x 38 25A. AM type
n° 3 d. 10 x 38 20A. AM type
Compressor resist. protect.
n° 1 d. 5 x 20 0,5A. rapid type
n° 1 d. 5 x 20 0,5A. rapid type
F2 primary transformer
n° 2 d. 5 x 20 2A. rapid type
n° 2 d. 5 x 20 6,3A. delayed type
F3 secondary transformer
n° 2 d. 5 x 20 6,3A. delayed type
n° 2 d. 5 x 20 6,3A. delayed type
Motor blocking protection
n° 2 d. 10 x 38 16A. delayed type
n° 2 d. 10 x 38 6A. delayed type
Fixed calibration high pressure switch
Int ervent ion pressure values (+ /-0,5 Bar)
Cout out pressure
20,7 Bar = 300 Psi
Connect pressure
13,8 Bar = 200 Psi
Dif f erent ial
6,9 Bar = 100 Psi
Safety Valve (11)
Intervention Bar 28
( + - 0,5 Bar)
REFRIGERATION PLANT WORKING PRESSURES AND TEMPERATURES
Condensation
Cycle startup
End of cycle (ice-cream ready)
+ 35° C = 12,5 Bar
95° F = 225 Psi
-20° C = 2 Bar
-5° F = 23,5 Psi
-33° C = 0,8 Bar
-27,4° F = 12 Psi
The machine is supplied with the above default values and settings.
TECHNOGEL CANNOT BE HELD LIABLE FOR ANY DAMAGE TO PROPERTY OR INJURY
TO PERSONS ARISING FROM CHANGES MADE TO THE DEFAULT SETTINGS OR FROM
THE USE OF CUTOUT FUSES OR FUSES WITH INCORRECT CHARACTERISTICS
OR IN ANY EVENT FUSES DIFFERING FROM THOSE PRESCRIBED.