Adjusting Sensitivity Levels
The Leak Detector will default to the
“NORM” sensitivity level
automatically once the unit comes out of the warm up cycle and
the green LED will turn on.
To change sensitivity levels, press the SENS once for
“HI”
sensitivity (red LED will turn on) and again for
“LO” sensitivity
(yellow LED will turn on).
Leak Test Vial
The leak detector comes with a Leak Test Vial that allows the
user to make sure the detector is performing properly.
To test the instrument
1.
Remove the colored label dot in the center of the screw
cap to expose the vent hole in the top of the screw cap.
(see fig. below)
2.
Turn on the detector and allow the unit to complete the
warm up cycle.
3.
Place the sensor close to the small hole in the top of the
Leak Test Vial. The beep rate should increase and the
Digital Leak Size Indicator should display a number from
3-6 indicating that the sensor and electronics are working
properly.
NOTE: Replace the Test Vial back in the nylon bag when
not in use to extend the shelf life. Replace Test Vial when
the green color is less than ¼ full or at the time of the
expiration
date.
4
Leak Test Vial
Remove label dot over
vent hole before testing
Expiration Date
on label
Vial Cap with vent
hole