5.

 Turn on the filter by pressing 

the  frequency  button 

.  A 

symbol  of  low  frequencies 
suppressing will appear on the 
display 

6.

  Using  the  buttons

  ◄/►

 

increase the frequency of the 
lower  «cut-off» 

  as 

long as it is not detrimental to 
the  intelligibility  of  the  sound 
in the headphones

7. 

Press 

the 

frequency 

button    .  A  symbol  of  higher 
frequencies  will  appear  on  the 
display  

 

8.

  Using  the  buttons

  ◄/►

 

decrease the frequency of the 
«cut-off» 

  as  long 

as  it  is  not  detrimental  to  the 
intelligibility of the sound in the 
headphones. 

9. 

Check  the  filtered  signal 

quality shown in the Spectrum 
graph 

(see  p.  4)

.  Highest 

number  of  black  stripes  (valid 
signal)    and  lowest  number 
of  light  stripes  (interference) 
signifies correct  choice of filter

10. Switch to Scale mode 
by pressing visual indication 
button  

.  Without changing 

the settings, examine the 
suspected leak area 

as 

described above in sections 
3.2 paragraphs 5-8

Frequencies where light segments prevail over the dark ones, are the most likely the 

interference frequencies that should be suppressed by pass band filter

4.

  Conduct an analysis of the generated spectrum

dark segments 

correspond 

to the frequency 

components of valid 

(continuous) signal

light to the frequency 

components of accidental 

interference

Leak point usually corresponds to a point where valid 

signal level is the highest.(fig.4.2).

If the same intensity of the signal level is observed at a 

distance of 2 to 5 m, then the leak point is located in the 
middle of such a segment.

11.

 Mark the suspected leak location.

12.

 Turn off the device

Fig.4.2

Summary of Contents for SUCCESS ATP-434N

Page 1: ......

Page 2: ...eceiver operability 8 4 2 Acoustic sensor AD 227 set contents 9 4 3 Conduct fine tuning of receiver filter 10 5 Operation sequence in passive cable route detection mode 12 5 1 Connection of sensors an...

Page 3: ...with magnetic base and extension rod which is used for pipe diagnostics in hard to reach places and survey of valves The method of operating the sensor ADM 227 is the same as with the sensor AD 227 Ex...

Page 4: ...s of the Receiver are listed in Appendix A Screen controls are listed in Appendix B Set of external PowerBank for example Xiaomi Mi Power Bank 20000 mAh with protective case and power adaptor SAMSUNG...

Page 5: ...end of the holder below protective rubber of the receiver 4 Put other end of the holder below the second rubber 5 The receiver is ready for the operation It is recommended to adjust the length of the...

Page 6: ...moved and the plugs should be placed back 3 Acoustic sensor AD 227 3 2 Structural and operation features of acoustic sensor Sensitive element of acoustic sensor is placed on steel sensing base later o...

Page 7: ...e sensor WARNING Using one key to install the rod is prohibited When using the rods please make sure that protective cuff fully touches the surface of the ground This helps to exclude the influence of...

Page 8: ...arge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol is lit on the display check if the sensor is connecte...

Page 9: ...We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the saved memory Appendix B select the areas with the hi...

Page 10: ...ode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launch window and then to return to the measurement mode...

Page 11: ...ference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the suspected leak area as described above in sections 3 2...

Page 12: ...ransport to operating position In order to do that loosen the locking nut 1 extend the bar 2 to a required length and fix with the locking nut 2 2 Loosen the locking nut 1 and install the electromagne...

Page 13: ...etup For tracing of energized cables please set frequency 50 Hz 1 Switch on the measurement mode using the button 5 Set input signal level using sensitivity buttons and Level at the bottom of the scal...

Page 14: ...rved when the sensor antenna passes directly above the utility line The maximum method is intended for a quick route location Flat peaks of the signal level curve do not allow for high location accura...

Page 15: ...of the utilities when the antenna axis intersects the axis of the route This is the indirect method of measuring the depth of utility fig 6 1 6 2 Task Detecting the pipeline and utility lines interse...

Page 16: ...nd parameters animated moving scale of the output signal level digital value and animated moving scale of the output signal level graphic moving diagram of the output signal level frequency content of...

Page 17: ...of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with AD sound of liquid leakage continuous acoustic signal sound generat...

Page 18: ...numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central frequency of the narrow band filter broadband Presence of the indicator...

Page 19: ...e and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the spectrum of the filtered signal When working with EMD switching the...

Page 20: ...dustrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of the signal 8 Memory window Fig 6 Fig 7 value of the valid signal...

Page 21: ...to the phones the adopted high active frequency 8192Hz and 33kHz before playing are converted into a well acceptable low frequencies of 838Hz and 1574Hz respectively Synthesized sound is created by a...

Reviews: