Do not switch the air conditioner back on immediately after switching it off -
wait a few minutes.
6.3 Cooling mode
The unit is ideal for hot, humid weather when it comes to cooling and dehumidifying
the room at the same time.
>
Press the
MODE
button (
1
) several times until "
Cool
" (
8
) lights up.
>
Select the target temperature (18 ° C to 32 ° C) by pressing the
Temperature
selection warmer / cooler
(
3
,
4
) button until the corresponding value is
shown on the display.
After switching on the unit and activating the cooling function, it may take a
moment for the compressor to start and the unit to start to cool.
>
Press the
FAN
button (
5
) several times to select the desired fan speed,
whereby
High
,
Medium
,
Low
and
Auto
(automatic control) can be selected.
Depending on the fan speed selected, the noise level of the air conditioning
unit while in operation will also change. If you prefer the unit to operate more
quietly, select
Low
.
If you turn on the cooling mode immediately after the heating mode has
been active, it can take up to 5 minutes before the unit starts to cool.
The most suitable temperature for the room during the summer is between
24 °C and 27 °C. However, it is recommended not to set a temperature that is
far below the temperature outside.
Both drain caps (9, 10) should be closed in this mode to allow efficient
cooling.
6.4 Heat mode
If you want to heat up a room, most probably in the cooler months, select heat
mode.
>
Press the
MODE
button (
1
) several times until "
Heat
" (
7
) lights up.
>
Select the target temperature (13 °C to 27 °C) by pressing the
Temperature
selection warmer / cooler
(
3
,
4
) button until the corresponding value is
shown on the display.
>
Press the
FAN
button (
5
) several times to select the desired fan speed,
whereby
High
,
Medium
,
Low
and
Auto
(automatic control) can be selected.
Depending on the fan speed selected, the noise level of the air conditioning
unit while in operation will also change. If you prefer the unit to operate more
quietly, select
Low
.
If you turn on the heating mode immediately after the cooling mode has
been active, it can take up to 5 minutes before the unit starts to heat.
Water is extracted from the air and collected in the tank. When the tank is
full, the unit switches off and the display shows
Ft
(full tank).
Summary of Contents for Technipolar 1
Page 1: ...TECHNIPOLAR 1 ...
Page 27: ...27 DE EN FR IT NL PL 13 Notizen ...
Page 28: ...28 ...
Page 53: ...53 DE EN FR IT NL PL 13 Notes ...
Page 54: ...54 ...
Page 79: ...79 DE EN FR IT NL PL 13 Notes ...
Page 80: ...80 ...
Page 105: ...105 DE EN FR IT NL PL 13 Appunti ...
Page 106: ...106 ...
Page 131: ...131 DE EN FR IT NL PL 13 Opmerkingen ...
Page 132: ...132 ...
Page 157: ...157 DE EN FR IT NL PL 13 Notatki ...
Page 158: ...158 ...
Page 159: ...159 DE EN FR IT NL PL ...
Page 160: ...M000 3956 ...