8 Basic command class
Members of association group 2 are controlled with Basic_Set commands of
the basic command class.
If the TechniSat series switch is
switched on
, a Basic_Set (
0 x FF
) command
is sent to members of
association group 2
.
If the TechniSat series switch is
switched off
, a Basic_Set (
0 x 00
)
command is sent to members of
association group 2
.
9 Notification command class
Notification
Event
Description
Power management
(0 x 08)
Inactive (0 x 00)
No event detected / event
cancelled
Overload detected
(0 x 08)
The maximum permissible
load on L1 / L2 was
exceeded
10 Supported Z-Wave command classes
Main device:
Command class
Version Required Z-Wave safety
levels
Association
2
highest permitted
Association group information
1
highest permitted