background image

Fig.6 Halogen unit 

Fig.7 

GENERAL 

Carefully read the following important information regarding installation 
safety and maintenance. Keep this information booklet accessible for 
further consultations. The appliance has been designed for use in the 
ducting version (air exhaust to the outside – Fig.A). 

SAFETY PRECAUTION 

1.

Take care when the cooker hood is operating simultaneously with an

open fireplace or burner that depend on the air in the environment and are 
supplied by other than electrical energy, as the cooker hood removes the 

Summary of Contents for CP750SS

Page 1: ...CP750SS ...

Page 2: ...ith the manufacturer s instructions Technika recommends that all Range Hood clearances be a minimum of 650mm to a maximum of 750mm between the top of the cooking surface and to the underside of the rangehood Distance may be reduced to 600mm to align with the AGA code ...

Page 3: ...LED lamp assembly LED lamp assembly Fig 4 Fig 5 ...

Page 4: ...cessible for further consultations The appliance has been designed for use in the ducting version air exhaust to the outside Fig A SAFETY PRECAUTION 1 Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and are supplied by other than electrical energy as the cooker hood removes the ...

Page 5: ...acent areas during or straight after use z Do not flambé under the Range Hood z Disconnect the electrical plug prior to any maintenance z This appliance is not intended for use by young children or infirm persons without supervision z Young children should be supervised to ensure they do not play with the appliance z There shall be adequate ventilation in the room when the Range Hood is used at th...

Page 6: ...ther appliances generated by other than an electrical source Before proceeding with the assembly operations remove the anti grease filter s so that the unit is easier to handle In the case of assembly of the appliance in the suction version prepare the hole for evacuation of the air USE AND MAINTENANCE It is recommended to operate the appliance prior to cooking It is recommended to leave the appli...

Page 7: ...Use a flat blade screwdriver or any other appropriate tool to lift and remove the overhead LED lamp fixture Replace the faulty 1 watt LED lamp Use only LED lamp assembly as the original specification Return the LED lamp fixture to its position Fig 4 Fig 5 COMANDS Fig 6 A OFF B SPEED I C SPEED II D SPEED III E LIGHT When pressing the key B the display light is flashing and please run in SPEED 1 If ...

Page 8: ... valve jammed Contact technician Motor cuts after a few minutes High temperature safety device activated The kitchen is not sufficiently ventilated The hood is installed too near the cooking stove The hood must be least 65cm from stove Oil dripping onto stove Oil cup full missing or not installed Remove aluminum grease filter and clean refit oil cup Aluminum grease filter saturated Wash the alumin...

Page 9: ...uld not be regarded as an infallible guide Actual product only should be used to derive cut out sizes All Technika Appliances must be installed by a qualified person s with adherence to the relevant electrical plumbing and AGA codes with compliance being issued as required by state or national legislation Additionally all Technika Upright cookers must have chains installed correctly in adherence t...

Reviews: