file:///E|/_MANUALS/TECHNICS/technics_sl-pd7nasvc_[ET]/NA/SL-PD7/SVC/s0100000000x.html[30/09/2009 12:14:25]
1 Safety Precaution
TOP
PREVIOUS
NEXT
(This “Safety Precaution” is applied only in U.S.A.)
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance
test to prevent the customer from being exposed to a shock hazard.
Insulation Resistance Test
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumper AC plug and each exposed metal cabinet
part, such as screw heads, antenna, control shafts, handle brackets, etc. Equipment with antenna terminals
should read between 3MO and 5.2MO toall exposed parts*. (Fig 1) Equipment without antenna terminals
should read approximately infinity to all exposed parts. (Fig 2)
*Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard. The equipment
should be repaired and rechecked before it is returned to the customer.
All manuals and user guides at all-guides.com
all-guides.com