background image

Before use

English

(05)

05

Caution for AC Mains Lead

(For the AC mains plug of three pins)
For your safety, please read the following text 
carefully.
This appliance is supplied with a moulded three 
pin mains plug for your safety and convenience.
A 10-ampere fuse is fitted in this plug.
Should the fuse need to be replaced please 
ensure that the replacement fuse has a rating 
of 10-ampere and that it is approved by ASTA 
or BSI to BS1362.
Check for the ASTA mark 

 or the BSI mark 

on the body of the fuse.
If the plug contains a removable fuse cover you 
must ensure that it is refitted when the fuse is 
replaced.
If you lose the fuse cover the plug must not be 
used until a replacement cover is obtained.
A replacement fuse cover can be purchased 
from your local dealer.

Before use

Remove the connector cover.

How to replace the fuse

The location of the fuse differ according to the 
type of AC mains plug (figures A and B).
Confirm the AC mains plug fitted and follow 
the instructions below.
Illustrations may differ from actual AC mains 
plug.

1. Open the fuse cover with a screwdriver.

 Figure A

 Figure B

 

 

 Fuse cover

2. Replace the fuse and close or attach the fuse 

cover.

 Figure A

 Figure B

 Fuse 
(10 ampere)

 

 Fuse 
(10 ampere)

Summary of Contents for SL-1200MK7

Page 1: ...SL 1210MK7 Operating Instructions Direct Drive Turntable System...

Page 2: ...erience we want to support the development and enjoyment of the world s many musical cultures This is our philosophy With a combination of our love of music and the vast high end audio experience of t...

Page 3: ...rmation Customer Communications Centre For customers within the UK 0333 222 8777 For customers within Ireland 01 447 5229 Monday Friday 9 00 am 5 00 pm Excluding public holidays For further support on...

Page 4: ...SS I construction shall be connected to a mains socket outlet with a protective earth connection Unit Do not place sources of naked flames such as lighted candles on this unit This unit may receive ra...

Page 5: ...the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A repl...

Page 6: ...nd recycling of old products please take them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and p...

Page 7: ...t 1 pc TYL0295 Head shell 1 pc TYL0331 Screw set for cartridge 1 set TTV0022 Nuts 2 pc Screws short 2 pc Screws long 2 pc Washers 2 pc Supplied in a bag PHONO cable 1pc K4EY4YY00003 PHONO earth lead 1...

Page 8: ...s 18 The LED lamps can be set to blue or red with the LED colour setting Factory setting Red 17 Turntable 10 Slipmat 10 Stylus light 19 EP record adaptor 18 Centre spindle 10 Insulator 13 START STOP b...

Page 9: ...o touch the stylus tip Screw for cartridge Head shell Lead wire Nuts Washers Lead wire Terminal Red R Red Green R Green White L White Blue L Blue Terminal Example Cartridge Stylus 2 Adjust the overhan...

Page 10: ...ip return the tone arm to the arm rest and fix it with the arm clamp Do not connect the AC mains lead until set up is complete When fitting the turntable prevent foreign material from getting in betwe...

Page 11: ...e turntable 2 Slowly set the turntable on the centre spindle Attention Be careful when handling the turntable as it is heavy Keep your fingers from being caught Wipe off fingerprints or dirt with a so...

Page 12: ...t on the connected equipment before using it for this unit For the power consumption of this unit see the specifications 23 The operation switch does not separate entire unit from mains even if in OFF...

Page 13: ...alled condensation Conditions causing condensation Rapid temperature change caused by moving from a warm place to a cold place or vice versa rapid cooling or heating or direct exposure to cooled air H...

Page 14: ...centre line of the rear of the tone arm Hold the balance weight still while doing this Preparation Return the tone arm to the arm rest and fix it with the arm clamp Horizontal balance Stylus pressure...

Page 15: ...rtridge The stylus pressure control will turn together with the balance weight Turn until the centre line points to the appropriate stylus pressure Centre line Balance weight Hold here to turn Turns t...

Page 16: ...ed For finer adjustment use a level not included to adjust the arm height so that the cartridge becomes parallel to a record 16 0 3 ANTI SKATING 3 4 Make this adjustment only if the cartridge you are...

Page 17: ...power plug Adjust as desired by setting the switches with a fine Phillips head screwdriver and the like ON OFF ON ON LED REV 78 TQ1 TQ2 BK1 BK2 1 2 3 4 5 6 7 8 Allows you to select red or blue for the...

Page 18: ...d adaptor Centre spindle 1 2 2 Preparation 1 Put a record not included on the turntable 2 Take off the stylus cover and release the arm clamp Strobe light Indicator 18 Attention Do not press START STO...

Page 19: ...the speed select button 45 45 lights Fit the EP record adaptor over the centre spindle When playing SP 78 rpm records Enable 78 rpm with the 78 rpm setting 17 Press the speed select buttons 33 and 45...

Page 20: ...volving Slide PITCH ADJ Pitch can be adjusted between approx 8 and 8 or approx 16 and 16 according to your selection The numbers represent approximate percentages for your adjustment Pitch range selec...

Page 21: ...t and carefully wrap them Remove the head shell and balance weight from the tone arm and carefully wrap them Clamp the tone arm with the arm clamp and tape it in place Carefully wrap the main unit in...

Page 22: ...ad shell s lead wires to the cartridge terminals correct Double check all connections 9 Humming is heard during play Are there other appliances or their AC mains lead near the stereo connection cable...

Page 23: ...switch 78 rpm Variable range pitch 8 16 Starting torque 1 8 kg cm Build up characteristics 0 7 s from standstill to 33 1 3 rpm Braking system Electronic brake Wow and flutter 0 025 WRMS Tone arm sect...

Page 24: ...Kadoma Osaka Japan Importer for Europe Panasonic Marketing Europe GmbH Panasonic Testing Centre Winsbergring 15 22525 Hamburg Germany Panasonic Corporation 2019 En TQBM0412 S0219AK1 Panasonic Corpora...

Reviews: