AC Power: 

This fixture runs on 110~220 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage to which 
you are connecting it is within the range of accepted voltages. 

 

 
Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat (variable 
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch.   
 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the 
fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its average 
current draw under normal conditions.   

 

 

Always connect the fixture to a circuit with a suitable electrical ground.   
 

To connect the power cord to the LGMEGAx plug the female side of the power cord into the power cord input which is 
on the rear of the unit. Then plug the male side of the power cord to an electric outlet. When linking LGMEGAx units to 
each other connect the power output on the first unit to power input on the next unit. 
The AC power cords supplied purposefully have 2 blades and one grounding prong. If your outlet is not equipped to 
handle this type of plug, do not attempt to forcefully plug this AC power cord into the outlet, and do not alter the plug so 
that it can fit in the outlet. The only course of action you can take is to find another outlet which is properly equipped to 
handle a grounded plug or have an electrician upgrade your electrical outlet. Be sure that the plug is well connected so 
that it does not disconnect in the middle of usage. If at any point in time the supplied AC power cord is punctured or 
damaged replace it with a new power cord from a local electrician. 

 

AC Power Linking: 

This fixture comes equipped with an AC Input (10) and AC Output (11) allowing you to link multiple fixtures together. 
The maximum quantity of fixtures that may be linked is 30. 

 

Fixture Linking via XLR Input / Output: 

You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run 
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of 
channels required by all the fixtures on a serial data link determines the number of fixtures the data link can 
support.   
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 standard, 
no more 
than 32 fixtures should be connected on one data link. Connecting more than 32 fixtures on one 
serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital 
DMX signal.   

Maximum recommended serial data link distance: 500 m (1640 ft)   
Maximum recommended number of fixtures on a serial data link: 32 
 

 
 
 
 
 
 
 
 
 

LGMEGAx 

Summary of Contents for LGMEGAx

Page 1: ...User Manual for Professional DJ Multi Pattern Laser LED Stage Effect Light With DMX MODEL LGMEGAx...

Page 2: ...isconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source 15 Secure fixture to fastening device using a safety chain 16 Maximum ambient temperature Ta...

Page 3: ...rmally deformed As receiving a fixture carefully unpack the carton checking contents to ensure that all parts are in good condition Informing the shipper immediately and retaining packing material for...

Page 4: ...imes prevents the unit from working at full performance or may even cause damages Don t install it on flammable object Don t use it when maximum ambient temperature is higher than 40 degree Unplug the...

Page 5: ...at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated The device should be well fixed a free swinging mou...

Page 6: ...unit is being operated in sound activated mode The fixture will illuminate changes according to the sound 10 Sensitivity Knob Use this knob to adjust the sensitivity of the lights when the fixture is...

Page 7: ...ug so that it can fit in the outlet The only course of action you can take is to find another outlet which is properly equipped to handle a grounded plug or have an electrician upgrade your electrical...

Page 8: ...female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S Maintaining the Fixture To maintain optimum performance and minimize wear fixtures should...

Page 9: ...ress up or down to get Aut3 Press enter to get Sxxx xxx stand for 000 100 press up or down to increase or decrease the number to control the motor rotate speed re press the enter to confirm the curren...

Page 10: ...utton until Soux x stand for0 1 6 press up or down to get Sou1 then press enter to confirm the current mode Sou4 RGBWA Mode Press the Func button until Soux x stand for0 1 6 press up or down to get So...

Page 11: ...ay Effect Operation Instruction Auto Aut0 laser RGBWA 8 W 1 Press Func to get Autx 2 press Enter to get Sxxx 001 100 to adjust the speed 3 Press Enter to confirm the current mode Aut1 laser RGBWA Aut2...

Page 12: ...Aut5 100 114 Aut6 115 129 Sou0 130 144 Sou1 145 159 Sou2 160 174 Sou3 175 189 Sou4 190 204 Sou5 205 219 Sou6 220 255 DMX mode work with CH2 3 4 5 6 7 8 CH2 All Auto modes 000 009 Blackout 010 014 Red...

Page 13: ...000 004 No function 005 254 Strobe slow fast work with CH1 CH2 255 Sound activated strobe mode CH5 8pcs white LED control 000 009 blackout 010 019 Picture1 slow fast 020 029 Picture2 slow fast 030 039...

Page 14: ...slave setup only ONE unit can act as the master ALL other fixtures must be set to d001 When using the master slave setup the fixtures can t be connected to a DMX controller as it would interfere with...

Reviews: