43
Installation and Maintenance
Service Manual
11. Removal Procedure
Caution: discharge the refrigerant
completely before removal.
a
b
Axile bush
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
Horizontal louver
Location of step motor
Procedure
Step
1.Remove filter assy
2. Remove horizontal louver
Front panel
Front
case
Right filter
Groove
Left filter
Open the front panel. Push the left and
right filters to make them break away
from the groove on the front case. Then
remove the left and right filters one by
one.
Screw off the 2 screws that are locking
the display board. Separate the display
board from the front panel.
Separate the panel rotation shaft from
the groove fixing the front panel and then
removes the front panel.
Panel
Screws
Display
Front panel
Panel rotation
Groove
3. Remove panel
09/12K