Technibel M2Z P Installation Instruction Download Page 3

GB

3

16

3

5

4

9

11

13

8

10

12

17

1

2

6

15

14

7

16

17

1

- Housing

2

- Mixing cylinder

3

- Automatic air vent valve

4

- Motorised, 3-way valve, zone 1

5

- Motorised, 3-way valve, zone 2

6

- Circulator, zone 1

7

- Circulator, zone 2

8

- Circuit breaker, zone 1

9

- Circuit breaker, zone 2

10

- Circulator terminal strip, zone 1

11

- Circulator terminal strip, zone 2

12

- Control board, zone 1

13

- Control board, zone 2

14

- Outlet water sensor, zone 1

15

- Outlet water sensor, zone 2

16

- Pressure taps for water output measurement, zone 1

17

- Pressure taps for water output measurement, zone 2

2 - PRESENTATION

2.1 - DESCRIPTION

74.5

43

107

600

750

260

665

251.5

170

130 120

635

15

15

185.5

240

127.5

6

5

4

3

7

2

1

2.2 - DIMENSIONS AND WEIGHT

1

Module water inlet connection (generator side)

Weight (kg)

2

Module water outlet connection (generator side)

39

3

Outgoing connection, zone 1

4

Outgoing connection, zone 2

5

Return connection, zone 1

6

Return connection, zone 2

7

Holes for electric cables

All connections are 1” male.

4 ø 9 holes
for wall
mounting

Front view

Left side view

Rear view

View from below

Summary of Contents for M2Z P

Page 1: ...ONAS SUELO HYDRAULIK MODUL F R 2 ZONEN FUSSBODEN HEIZUNG ODER K HLUNG M DULO 2 ZONAS SOALHO Mars 2009 10 11 465 F GB I E D P 02 Etiquette signal tique F GB I E D P NOTICE D INSTALLATION INSTALLATION I...

Page 2: ...s of all current directives laws and regulations and according to recognized trade practices 1 3 VOLTAGE Before all operation check that the voltage indicated on the appliance rating plate corresponds...

Page 3: ...ter sensor zone 2 16 Pressure taps for water output measurement zone 1 17 Pressure taps for water output measurement zone 2 2 PRESENTATION 2 1 DESCRIPTION 74 5 43 107 600 750 260 665 251 5 170 130 120...

Page 4: ...Use the cable glands mounted on the unit see 4 2 4 Ensure that all installation grounds are interconnected Cables are not supplied Consult the module electrical diagram Also consult the installation...

Page 5: ...ocation that is representative of the temperature in zone 1 Caution In this case the remote zone 1 sensor must be activated through parameterisation on the control unit refer to control s technical ma...

Page 6: ...GURATION SETTING Set the button on the installation s control box to OFF Turn installation and module power on On the control unit configure the system for the 2 Floor Zones application parameter 70 2...

Page 7: ...leeders located in the 2 zone module and heating module CAUTION An incorrect purge could result in malfunctions and damage to the heater of the heating module 0 10 20 30 40 50 60 70 80 90 0 0 5 1 1 5...

Page 8: ...RAL MAINTENANCE All equipment must be properly maintained in order to provide optimum performance over time Faulty maintenance can result in the cancellation of the product guaranty Depending on the p...

Page 9: ...GB 9...

Page 10: ...F GB D P I E...

Page 11: ...F GB D P I E...

Page 12: ...dificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert...

Reviews: