8
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Power Surce.......Voltage Rating 400V - 3N - 50Hz .. ....400 V
Control Circuit 230 V 50Hz
Cooling
Capacity
kW 5.0
BTU/h 17
1
00
Air circulation (High) m
3
/h 800
Moisture removal (High) Liters/h 2.
3
Available voltage range V 342 to 418
Running amperes A 3.6
Power input W 2000
Power factor % 80
C.O.P. W/W 2.50
Compressor locked rotor amperes
21.5
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON/OFF 24 hours & Daily program, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / Auto (Hi, Lo)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 1710
Refrigerant control Capillary tube
Noise Power Level
Indoor – Hi / Me / Lo dB-A 48 / 44 / 49
Outdoor – Hi dB-A 51
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment m 10
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube mm (in.) 12.7 (1/2)
Refrigerant tube kit Optional
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 680 630
Width mm 900 830
Depth mm 190 305
Package dimensions Height mm 813 713
Width mm 1011 994
Depth mm 296 413
Weight Net kg 23.5 52.0
Shipping
kg 30.0 57.0
Shipping volume m
3
0.24 0.29
Dimensions & Weight
Features
Electrical Rating
Performance
Outdoor Unit
GRV180L7TAA
Indoor Unit
KPAV180C5VAA