3. DIMENSIONAL DATA

GR9FI50R5IAA

GR9FI50R5IAB

GR9FI42R5IAA

dimension [mm]

WIDE TUBE

2x ø.9,52 (3/8")

NARROW TUBE

2x ø.6,35 (1/4")

4 - Ø12
for anchor bolt

8

Summary of Contents for GR9FI42R5IAA

Page 1: ...ICE MANUAL OUTDOOR UNIT GR9FI50R5IAA GR9FI50R5IAB GR9FI42R5IAA DUAL SPLIT SYSTEM AIR CONDITIONER 0 8180 597 03 09 2012 Model No Product Code No GR9FI50R5IAA 38 7107 098 GR9FI50R5IAB 38 7107 103 GR9FI4...

Page 2: ...t allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of...

Page 3: ...W DIAGRAM 9 4 1 Dual Split System Refrigerant Flow Diagram 9 4 2 Mono Split System Refrigerant Flow Diagram 10 5 PERFORMANCE DATA 11 5 1 Performance Charts 11 12 13 6 ELECTRICAL DATA 14 6 1 Electrical...

Page 4: ...GR9FI50R5IAB Heating Maximum 27 C D B Temperature Indoor Air Intake Temp GR9FI42R5IAA 24 C D B 18 C W B Minimum 5 C D B 15 C D B Outdoor Air Intake Temp Cooling Maximum 32 C D B 23 C W B 43 C D B Mini...

Page 5: ...ANGE WITHOUT NOTICE Remarks Rating Conditions are Cooling Indoor Air Temperature 27 C D B 19 C W B Outdoor Air Temperature 35 C D B 24 C W B Heating Indoor Air Temperature 20 C D B Outdoor Air Tempera...

Page 6: ...ose C Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WITHOUT NOTICE CHANGE WITHOUT NOTICE 1 5 0 47 2 Propeller 1 400 BOM ZW465B57 8 variable 200 800 Micropro...

Page 7: ...mistor narrow tube B sensor Resistance k Crank case heater Resistance at 20 C Base heater Resistance at 20 C DATA SUBJECT TO CHANGE WITHOUT NOTICE CHANGE WITHOUT NOTICE 10 at 25 C NTC THERMISTOR 10 at...

Page 8: ...3 DIMENSIONAL DATA GR9FI50R5IAA GR9FI50R5IAB GR9FI42R5IAA dimension mm WIDE TUBE 2x 9 52 3 8 NARROW TUBE 2x 6 35 1 4 4 12 for anchor bolt 8...

Page 9: ...e is used in the outdoor unit both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated w...

Page 10: ...both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated with a proper insulation mater...

Page 11: ...0 1 50 10 15 20 25 30 35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressu...

Page 12: ...35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressure at wide tube servi...

Page 13: ...35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressure at wide tube servi...

Page 14: ...Outdoor Air Temperature 7 C D B 6 C W B NOTE Data referred to 2 indoor unit MTAF B IA0R5I x2 For other indoor unit models there could be some differences GR9FI42R5IAA COOLING 2 Indoor Unit Fan Motor...

Page 15: ...6 2 Electric Wiring Diagram Outdoor unit GR9FI50R5IAA PRODUCED BEFORE DEC 31 2010 Outdoor unit GR9FI50R5IAA PRODUCED AFTER GEN 1 2011 GR9FI50R5IAB GR9FI42R5IAA 15...

Page 16: ...Outdoor unit GR9FI50R5IAA PRODUCED AFTER GEN 1 2011 GR9FI50R5IAB GR9FI42R5IAA Indoor unit MTAF B IA0R5I x2 6 4 Mono Split System Wiring Diagram Outdoor unit GR9FI50R5IAA PRODUCED BEFORE DEC 31 2010 I...

Page 17: ...C NOTES The troubles are showed according to a priority list that is in case of more than one trouble present is always showed at first the one with the highest priority 3 2 1 etc Sensor damaged mean...

Page 18: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...