26
5-3. Cooling Capacity
Indoor Unit MCAV77C5VAB
Outdoor Unit GR79C5TBA
230V Single Phase 50Hz
RATING CAPACITY
2.05 kW
AIR FLOW RATE
430 m
3
/h
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
20
25
30
35
40
45
TC
2.07
1.98
1.89
1.80
1.69
1.55
CM
0.42
0.45
0.48
0.52
0.57
0.61
21
SHC
1.50
1.46
1.42
1.38
1.33
1.27
15
23
SHC
1.72
1.68
1.63
1.59
1.54
1.48
25
SHC
1.94
1.89
1.85
1.80
1.69
1.55
27
SHC
2.07
1.98
1.89
1.80
1.69
1.55
29
SHC
2.07
1.98
1.89
1.80
1.69
1.55
31
SHC
2.07
1.98
1.89
1.80
1.69
1.55
TC
2.22
2.12
2.02
1.93
1.81
1.67
CM
0.43
0.46
0.50
0.53
0.58
0.63
21
SHC
1.28
1.24
1.20
1.15
1.10
1.04
17
23
SHC
1.50
1.45
1.41
1.37
1.32
1.26
25
SHC
1.71
1.67
1.63
1.59
1.54
1.48
27
SHC
1.93
1.89
1.84
1.80
1.75
1.67
29
SHC
2.15
2.10
2.02
1.93
1.81
1.67
31
SHC
2.22
2.12
2.02
1.93
1.81
1.67
TC
2.36
2.26
2.15
# 2.05
1.93
1.77
CM
0.44
0.48
0.51
0.55
0.60
0.65
21
SHC
1.05
1.01
0.96
0.92
0.87
0.81
19
23
SHC
1.27
1.22
1.18
1.14
1.09
1.03
25
SHC
1.48
1.44
1.40
1.36
1.31
1.25
27
SHC
1.70
1.66
1.61
1.57
1.52
1.46
29
SHC
1.92
1.87
1.83
1.79
1.74
1.68
31
SHC
2.13
2.09
2.05
2.01
1.93
1.77
TC
2.50
2.39
2.28
2.17
2.04
1.88
CM
0.46
0.49
0.53
0.57
0.61
0.66
23
SHC
1.03
0.99
0.95
0.91
0.86
0.80
21
25
SHC
1.25
1.21
1.17
1.13
1.08
1.02
27
SHC
1.47
1.42
1.38
1.34
1.29
1.24
29
SHC
1.68
1.64
1.60
1.56
1.51
1.45
31
SHC
1.90
1.86
1.82
1.78
1.73
1.67
TC
2.65
2.54
2.42
2.28
2.14
1.99
CM
0.46
0.51
0.54
0.58
0.63
0.68
23
25
SHC
1.01
0.96
0.92
0.88
0.83
0.78
27
SHC
1.22
1.18
1.14
1.09
1.04
0.99
29
SHC
1.44
1.40
1.36
1.31
1.26
1.21
31
SHC
1.66
1.61
1.57
1.53
1.48
1.43
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
Summary of Contents for GR129C5TBA
Page 35: ...KPAV128C5TAA L Indoor Unit 32...