4-9 I FEEL Function
As standard configuration the air conditioner operates detecting the room temperature through the sensor
equipped in the wireless remote controller (icon I FEEL shown on the display). This feature provides a
personalised environment since the temperature can be detected where the remote controller is located.
It is possible to de-activate this option pressing the I FEEL button on the remote controller.
In this case the I FEEL icon is no longer displayed and room temperature is detected through the sensor
included in the indoor unit.
4-10 NIGHT Function
When this function is active, room temperature changes automatically to compensate for body temperature
variations while sleeping. After 10 hours of operation system switches automatically to OFF state.
This mode of operation is available both in COOLING and HEATING mode.
4-11 DRAIN PUMP Mode
This unit is equipped with a drain pump
The level detection is done through a float switch connected at the input WS (closed under normal condition,
and opened when water overflow). System operation is according to the following chart:
OPERATION
led
CM
FMO
Open
Closed
Blink
ON
OFF
Overflow when
THERMO is ON
Overflow when
THERMO is OFF
ON
OFF
Drain
pump
ON
OFF
Thermostat
ON
OFF
Overflow when
unit is OFF(standby)
T < 10 min
29