11 - "ECH" ELECTRONIC CONTROL

• Microprocessor control module, including:

- chilled water temperature control (water inlet),
- control of operating parameters,
- self-adapting algorithm for water volume reduction,
- circulating pump control (frost protection and anti-sticking function),
- dynamic setpoints are possible according to the outside temperature (to be activated at the time of installation by means

of special parameterization).

- anti-short cycle system,
- hour counter compressor and circulating pump,
- alarm management,
- anti-freeze security (temperature probes at water exchanger outlet),
- digital display of:

. water temperature,
. set-point,
. alarm code (HP, LP, water output, probes, anti-freeze...).

- remote alarm reporting is possible via a potential-free contact,
-

integrated condensation pressure control

(with pressure sensors),

- remote control with display unit (accessory),
- serial communications port (RS 485 interface, accessory) - MODBUS Protocol.

12 - INSTALLATION INFORMATION

• See details in the installation manual.

12.1 - INSTALLATION

• Protection index of the unit:

- IP 24 

: for the electrical equipment,

(IPXXB : for the mechanical hazards). 

• Before installation, verify the following points:

- the unit must be installed outside in an appropriate location and in compliance with environmental requirements (sound

level, integration, etc...), 

- the water chiller’s installation location must be perfectly level and strong enough to support the weight of the unit and

must have adequate inundation protection,

- sufficient space around the unit should be provided in order to facilitate servicing and maintenance operations,
- air suction to the coil and fan discharge must not be obstructed,
- install the unit above the region’s average snowfall level,
- vibrations and noise must not be transmitted to adjacent buildings,
- install the machine on anti-vibration pads and fit hoses on piping elements, as required,
- if necessary, consult an acoustics specialist concerning the unit’s optimum location,
- 4 holes Ø 22.5 enable to place hoisting hooks and lift the unit.

12.2 - ELECTRICAL CONNECTIONS

• All required information is indicated on the electrical diagram provided with the unit and in the installation manual.
• Connections are to be made in compliance with the standard code of practice and as per the standards in force at the site

of installation.

12.3 - HYDRAULIC CONNECTIONS

• The hydraulic connections are to be made in compliance with the standard code of practice.

IMPERATIVE:

Install the filter supplied on the water inlet of the unit.

12.4 - STARTING - MAINTENANCE

• Refer to the installation guide and the maintenance manual.

IMPORTANT:

- The unit's electronic control features a frost protection device that automatically starts the water circulating pump

depending on the outside temperature (adjustable threshold), even if the unit is turned off.

- In the event the unit may be taken out of service or in the case of a high risk of freezing:

- either drain the installation,
- or add glycol to the circuit.

- Tank anti-freeze resistance:

its electrical power supply and control must be separate from those of the unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CHGV 50

Page 1: ...CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR WATER 47 to 78 kW CHGV 50 CHGV 64 CHGV 72 CHGV 80 November 2007 10 12 167 GB 02 TECHNICAL INSTRUCTIONS PHRV heat pump model also available...

Page 2: ...the compressor MAINTENANCE INSTRUCTIONS 1 Never add oil to the appliance the compressor is filled with polyalcohol oil a special oil which cannot tolerate the presence of other oils 2 The instruments...

Page 3: ...1 per circuit ELECTRIC FAN UNIT Electric fan unit with protective grille 1 per circuit SWITCH BOX ECH electronic control Main switch Phase sequence tester Power and control circuitry protected by mag...

Page 4: ...sumption Effictuiveness heating Rated total input amperage Total Max power consumption Total Max current consumption Starting current Gross value without hydraulic pump In the operating range Power su...

Page 5: ...attachment 300 300 1000 300 600 with tank Clearances to be respected for unit operation and maintenance No obstacle less than 3 m above the unit Front Net Packed weight weight Length 2 015 mm 50 500...

Page 6: ...d not installed Circulating pump Maximum power consumption pump only kW 1 40 1 40 1 90 1 90 Maximum current A 2 70 2 70 3 50 3 50 Power supply 400V 3 50Hz Electrical equipment IP 24 IP 24 IP 24 IP 24...

Page 7: ...put power kW Water outlet temperature C Cooling capacity kW Water outlet temperature C Total input power kW Water outlet temperature C Cooling capacity kW Water outlet temperature C Total input power...

Page 8: ...5 mm code 70600035 1 set of 2 flexible hoses length 1 5 m 1 1 2 code 70600034 IMPORTANT Use monopropylene glycol a minimum rate of 15 to 20 is needed to avoid any risk of corrosion PRINCIPLE OF USING...

Page 9: ...heating with 800 W anti freeze resistance single phase 230 VAC Designed to be installed either underneath the unit or separately For installation underneath the unit the tank is supplied with mounting...

Page 10: ...ve adequate inundation protection sufficient space around the unit should be provided in order to facilitate servicing and maintenance operations air suction to the coil and fan discharge must not be...

Page 11: ...11...

Page 12: ...icy of continuous development our products are liable to modification without notice R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France Phone 33 4 74 00 92 92 Fax 33 4 74 00 42 00 R C S Bourg en Bresse...

Reviews: