3.3 - REMOVING THE FAN ASSEMBLY
• Remove the fastening screws.
• Disconnect the loom at connector A.
• Pull the fan assembly.
3.5 - CHOOSING THE BLOWING DIRECTION
3.5.1 - STANDARD DELIVERY
• Vertical backward blowing.
3.5.2 - FORWARD BLOWING
• Turn the grille 180° (see "Removal" page 6).
FORWARD BLOWING
BACKWARD BLOWING
Rubber block
3.4 - MOUNTING
• The device must be installed in vertical position and level.
It must always
be installed fastened
(to the floor or on a wall mounting).
• For assembly on a wall mounting, refer to the accessories chapter for the
mounting to be used.
• For secure fastening, it can be fastened to a wall using the screws and pins
supplied with the device (2 fastening holes on the rear mounting).
• It must be fitted flush against a wall in all cases.
• To prevent the transmission of vibrations to the floor, you are recommended
to put rubber blocks under the unit.
• These 4 supplied blocks are to be put by the 4 pressings acting as feet, as
indicated opposite.
• The unit is raised by 5 mm.
Pressings acting as
feet
Rubber block
3.3 - CHOOSING THE LOCATION
AVOID:
• Putting the unit in very damp places. This unit is designed to be installed in
sheltered rooms (IP 20).
• Direct exposure to sunlight or the proximity of heat sources.
• Installing the unit behind curtains or furniture which could prevent air
circulation.
• Installing the device near inflammable materials (as it can be equipped with
an electric heater).
MAKE SURE THAT:
• The position is the best one for providing good ventilation in the room.
• The position chosen complies with the recommended minimum mainte-
nance spaces (see drawing opposite).