OUTDOOR UNIT:
GRF128R5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,13
0,28
4,99
5,40
Power input
Kw
0,031
0,063
0,966
1,060
Full load conditions
Running Amps.
A
0,13
0,28
5,89
6,30
Power input
Kw
0,031
0,063
1,206
1,300
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,13
0,28
4,8
5,20
Power input
Kw
0,031
0,063
0,931
1,025
Full load conditions
Running Amps.
A
0,13
0,28
5,89
6,30
Power input
Kw
0,031
0,063
1,206
1,300
Rating Conditions:
Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions: Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
NOTE: Data referred to indoor unit
MRAF128R5TAA
model.
For other indoor unit models there could be some differences.
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz
23