2. ELECTRICAL DATA
6-1 Electrical characteristics
OUTDOOR UNIT:
GRF78R5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,11
0,28
2,61
3,00
Power input
Kw
0,025
0,063
0,562
0,650
Full load conditions
Running Amps.
A
0,11
0,28
3,51
3,90
Power input
Kw
0,025
0,063
0,742
0,830
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,11
0,28
2,51
2,90
Power input
Kw
0,025
0,063
0,542
0,630
Full load conditions
Running Amps.
A
0,11
0,28
3,51
3,90
Power input
Kw
0,025
0,063
0,742
0,830
Rating Conditions:
Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions: Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
NOTE: Data referred to indoor unit
MRAF78R5TAA
model.
For other indoor unit models there could be some differences.
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz
21