1.  General

This booklet briefly outlines where and how to install

the air conditioning system. Please read over the

entire set of instructions for the indoor and outdoor

units and make sure all accessory parts listed are with

the system before beginning.

1-1.  Tools Required for Installation (not supplied)

1. Standard screwdriver

2. Phillips head screwdriver

3. Knife or wire stripper

4. Tape measure

5. Carpenter’s level

6. Sabre saw or key hole saw

7. Hacksaw

8. Core bits

9. Hammer

10. Drill

11. Tube cutter

12. Tube flaring tool

13. Torque wrench

14. Adjustable wrench

15. Reamer (for deburring)

1-2.  Accessories Supplied with Unit 

Table 1

1-3.  Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the

indoor unit is available in kits which contain the narrow

and wide tubing, fittings and insulation. Consult your

nearest sales outlet or A/C workshop.

1-4.  Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately

from a local source, you will need:

1.

Deoxidized annealed copper tube for refrigerant

tubing as detailed in Table 2.

Cut each tube to the appropriate l30 cm

to 40 cm to dampen vibration between units.

Table 2

2.

Foamed polyethylene insulation for the specified

copper tubes as required to precise length of tub-

ing. Wall thickness of the insulation should be not

less than 8 mm.

3.

Use insulated copper wire for field wiring. Wire

size  varies with the total length of wiring. Refer to

3-6. Wiring Instructions for details.

Part

s

Fi

g

ure

Q’ty

1

1

1

4

2

AAA alkali

n

battery

Remote 
co

n

trol 

un

it

Remote co

n

trol 

un

it holder

Part

s

Fi

g

ure

Q’ty

Tappi

ng

 

s

crew

Clamp

Tappi

ng

 

s

crew

Tr

uss

-head

Phillip

s

3

0 mm

Tr

uss

-head

Phillip

s

4  16 mm

2

8

C

us

hio

n

r

u

bber *

Air clea

n

 filter

Part

s

Fi

g

ure

Q’ty

1

Drai

n

 elbow *

5

GRF246

4

GRF1

8

6

*

Packed i

n

 the o

u

tdoor 

un

it.

Drai

n

 cap

*

2

(1 each)

CAUTION

Check local electrical codes

and regulations before

obtaining wire. Also, check

any specified instructions or

limitations.

Model

Narrow Tube

Wide Tube

Outer Dia.

Thickness

Outer Dia.

Thickness

MCAF186

6.35 mm

0.8 mm

12.70 mm

0.8 mm

MCAF246

6.35 mm

0.8 mm

15.88 mm

1.0 mm

06-154 MCAF186 - 246R5I ENG  3/15/06  11:04 AM  Page 3

Summary of Contents for MCAF186

Page 1: ...5 3 Caution before Connecting Tubes Tightly 5 4 Connecting Tubing between Indoor and Outdoor Units 5 5 Insulation of Refrigerant Tubing 5 6 Taping the Tubes 5 7 Finishing the Installation 6 AIR PURGI...

Page 2: ...oor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fin gers When Installing In a Ceili...

Page 3: ...ocal source you will need 1 Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2 Cut each tube to the appropriate lengths 30 cm to 40 cm to dampen vibration between units Tabl...

Page 4: ...ed in Table 3 and Fig 3a G Install the indoor unit more than 1 meter away from any antenna or power lines or connecting wires used for televi sion radio telephone security system or intercom Electrica...

Page 5: ...nd possible maintenance Fig 5a or 5b G provide a solid base level concrete pad concrete block 10 40 cm or 15 40 cm beams or equal a minimum of 10 cm or 15 cm above ground level to reduce humidity and...

Page 6: ...p on page 14 3 2 Make a Hole 1 Place the rear panel from the indoor unit on the wall at the location selected Make sure the panel is horizontal using a carpenter s level or tape mea sure to measure do...

Page 7: ...pend the unit See either Item a or b below depending on the wall type a If Wooden Wall 1 Attach the rear panel to the wall with the 8 screws provided Fig 13 If you are not able to line up the holes in...

Page 8: ...first Fig 18b Then insert the tabs on the top of the grille and on the front face into the frame 2 Make sure that the grille and frame are firmly fitted together by engaging the tabs 3 Attach the ther...

Page 9: ...r outlet to be used exclusively for each unit with a power supply disconnect and cir cuit breaker for overcurrent protection provided in the exclusive line 3 To prevent possible hazard due to insulati...

Page 10: ...nect the power supply line to the outdoor unit as shown in the wiring diagram The indoor unit draws its power from the outdoor unit G Do not run wiring for antenna signal or power lines of television...

Page 11: ...Route the inter unit wiring from the back of the indoor unit and pull it toward the front for connec tion Fig 26 5 Connect the inter unit wiring to the corresponding terminals on the terminal plate F...

Page 12: ...4 Shape the loop wire properly place it on the ter minal plate and fix it securely with the removed terminal screw using a screwdriver I For stranded wiring 1 Cut the wire end with a cutting pliers t...

Page 13: ...through the hole in the wall Adjust the indoor unit so it is securely seated on the rear panel Fig 36 3 Carefully bend the tubing if necessary to run along the wall in the direction of the outdoor uni...

Page 14: ...fully onto the drain pan outlet until the drain hose edge is pushed into the insu lation Check that the screw holes in the drain bracket and the drain pan outlet are aligned and securely in contact t...

Page 15: ...ain hose will run in the room insulate the hose with insulation so that chilled condensation will not damage furniture or floors Fig 44 Foamed polyethylene or its equivalent is recom mended WARNING Ri...

Page 16: ...ig 46 2 Connect the inter unit wiring and power line according to the drawing on the panel side 3 Be sure to size each wire allowing approx 10 cm longer than the required length for wiring Store exces...

Page 17: ...49b Use RIGID or equivalent A good flare should have the following characteristics G inside surface is glossy and smooth G edge is smooth G tapered sides are of uniform length 5 3 Caution before Conne...

Page 18: ...bing overlap half of each previous tape turn Fig 55 3 Clamp the tubing bundle to wall using 1 clamp approx every 120 cm Do not wind the armoring tape too tightly since this will decrease the heat insu...

Page 19: ...tion Table 7 Hi Lo Indoor unit Outdoor unit Manifold valve Exclusively for R410A Pressure gauge Vacuum pump Charging hose Exclusively for R410A Vacuum pump adapter Exclusively for R410A with reverse f...

Page 20: ...e pressure Then remove the hose 11 Fasten the valve cap on the wide tube service port securely with an adjustable wrench or box wrench Next mount the valve cap on the service valve and tighten it to 2...

Page 21: ...ed forced air with the 4 indicator lamps OPERATION lamp TIMER lamp and QUIET lamp on the main unit blinking Fig 59c After 3 minutes the system shifts into cooling operation and cool air will start to...

Page 22: ...ube valve stem Then quickly stop the unit 5 Disconnect all gauges and hoses and replace the valve caps as they were before I Basic Functions of the Service Valves The basic functions of the service va...

Page 23: ...le between the remote control unit and the air conditioner since a check signal is sent from the remote control unit every 5 minutes 7 1 Mounting on a Wall Before mounting the remote control unit pres...

Page 24: ...est run appears blinking in the remote controller clock display area 4 Each time the 1 HR TIMER button is pressed the display changes as shown below Press this but ton 2 times to change the display to...

Page 25: ...MISTOR COMPRESSOR THERMISTOR COMPRESSOR MOTOR RED WHT BLU RED WHT BLU FERRITE CORE FERRITE CORE 3P CONNECTOR OVERLOAD RELAY OLR WHT WHT Indoor Unit MCAF186 8FA2 5257 82800 0 EVAPORATOR TERMINAL BASE W...

Page 26: ...ORE 3P CONNECTOR OVERLOAD RELAY OLR WHT WHT 8FA2 5257 82800 0 EVAPORATOR TERMINAL BASE WHT BLK RED 1 2 3 4 GRN YEL LAMP 10P WHT FLAP 5P WHT FLAP CONNECTOR FLAP MOTOR RED PNK BLU BRN YEL 1 2 3 4 5 1 2...

Page 27: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France Tel 33 04 74 00 92 92 Fax 33 04 74 00 42 00 http www technibel com 06 155 MCAF186 246R5I FRA 3 15 06 1 45 PM Page 28...

Reviews: